Capacitors supply in Torshavn
Torshavn is the capital of the Faroe Islands and a smaller city. The climate is cold. Summers are short and mild, and winters are long and often well below freezing.
The main users of capacitors in Torshavn are offices, shops and malls as well as factories and workshops. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Torshavn for a quotation.
- Country
- Faroe Islands
- Population
- 13,000
- Climate
- Cold
- Coordinates
- 62.0° N, 6.8° W
- Time zone
- UTC+0, moving to UTC+1 while daylight saving applies
- Supply
- 230 V, 50 Hz
- Status
- National capital
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Torshavn · Klima Capacitors overview
Conditions in Torshavn that affect capacitors
In Torshavn, cooling is mostly for process, commercial and cold-chain needs rather than comfort. Low temperatures make plastics brittle and slow some electrical parts; let cold capacitors warm up before fitting where you can, and never force a terminal.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
About supply to Torshavn
Torshavn is the only city listed for the Faroe Islands, with about 13,000 people. Enquiries from anywhere in the country can use this page.
In a smaller city like Torshavn, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Torshavn
Torshavn keeps UTC+0, moving to UTC+1 while daylight saving applies.
Sunlight at 62.0° N (Torshavn): about 19 h 45 min of daylight in June, about 5 h 08 min in December, and a noon sun that reaches 51° in June and 5° in December. The sun stays lower in the sky, so wind, snow and frost matter more than shade for outdoor units.
Where capacitors are used in Torshavn
Capacitors are most often specified in Torshavn for:
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
- Ventilation and exhaust fan motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Torshavn
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- For cold conditions in Torshavn, check the low-temperature limits on the datasheet.
Care and maintenance in Torshavn
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
The warm season in Torshavn is short, normally from June to August, while refrigeration and heating work through the cold months. Check capacitors in April or May and again before winter. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Torshavn
Shipments for Torshavn normally clear customs at one of the main entry points of the Faroe Islands and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for the Faroe Islands are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Torshavn: common questions
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in Torshavn?
The Faroe Islands supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Torshavn?
To order capacitors for Torshavn, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Torshavn can I order for?
Enquiries are welcome from every part of Torshavn. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Torshavn?
Torshavn keeps UTC+0, moving to UTC+1 while daylight saving applies. At 62.0° N there are about 19 h 45 min of daylight in June and about 5 h 08 min in December.