Klima capacitors for Tours
Found in France, Tours is a smaller city with a temperate climate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
Demand for capacitors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Tours for a quotation.
- Country
- France
- Population
- 142,000
- Climate
- Temperate
- Coordinates
- 47.4° N, 0.7° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Paris
- 203 km south-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Tours · Klima Capacitors overview
What Tours demands of capacitors
In Tours, cooling demand is seasonal, with short hot spells that stress equipment. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Where capacitors go from Tours
Tours ranks 37th of the 41 listed cities in France and holds about 1.3% of the people living in them, roughly 6.6% of the size of the largest city, Paris. The capital, Paris, is about 203 km away, to the north-east of Tours. It is about the same size as Bondoukou in Ivory Coast, which has 142,000.
The closest are Le Mans (77 km north-west), Angers (95 km west) and Nantes (171 km west). Two other listed cities lie within 100 km, and 23 within 300 km. The farthest listed city in France is Nice, about 655 km south-east of Tours.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Le Mans | 77 km north-west | 145,000 | moisture on terminals and corrosion |
| Angers | 95 km west | 168,000 | expansion and contraction loosening joints |
| Nantes | 171 km west | 325,000 | moisture on terminals and corrosion |
| Limoges | 178 km south | 141,000 | expansion and contraction loosening joints |
| Saint-Quentin-en-Yvelines | 182 km north-east | 147,000 | moisture on terminals and corrosion |
| Rennes | 195 km north-west | 228,000 | moisture on terminals and corrosion |
In a smaller city like Tours, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Daylight and sun angle in Tours
Tours keeps UTC+1, moving to UTC+2 while daylight saving applies.
At 47.4° N, Tours has about 15 h 57 min of daylight at the June solstice and about 8 h 27 min at the December solstice. The noon sun stands 66° above the horizon in June and 19° in December, and the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Tours is temperate, in line with the rest of France; 34 other listed cities share it.
Typical uses of capacitors in Tours
In Tours, these are the jobs that most often call for capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Tours
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Confirm the supply first: France uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Tours
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check capacitors in Tours. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Tours
Shipments for Tours normally clear customs at one of the main entry points of France and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for France are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Tours: common questions
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Tours?
France supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Tours?
To order capacitors for Tours, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Tours can I order for?
Enquiries are welcome from every part of Tours. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Tours?
Tours keeps UTC+1, moving to UTC+2 while daylight saving applies. At 47.4° N there are about 15 h 57 min of daylight in June and about 8 h 27 min in December.
Which cities near Tours can the same order serve?
The listed cities closest to Tours are Le Mans (77 km north-west), Angers (95 km west) and Nantes (171 km west). Combine them into one order and give each delivery address.
More Klima products for Tours
- Klima Contactors in Tours
- Klima Terminal Crimps in Tours
- Klima Transformer for HVAC in Tours
- Klima PVC Tapes in Tours
- Klima Temperature Controllers in Tours
- Klima Thermostat Guards in Tours