Klima capacitors for Stuttgart
Stuttgart is a mid-sized city in Germany. The climate is temperate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
Capacitors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Stuttgart for a quotation.
- Country
- Germany
- Population
- 613,000
- Climate
- Temperate
- Coordinates
- 48.8° N, 9.2° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Berlin
- 512 km south-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Stuttgart · Klima Capacitors overview
Conditions in Stuttgart that affect capacitors
In Stuttgart, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Capacitors in Stuttgart and the cities near it
By population Stuttgart is 7th of the 44 cities listed for Germany, with roughly 2.8% of their combined population, roughly 18% of the size of the largest city, Berlin. From Berlin, the capital, Stuttgart is roughly 512 km to the south-west. For scale, Las Pinas in the Philippines has a similar population (616,000).
Nearest to Stuttgart: Karlsruhe (62 km north-west), Mannheim (94 km north-west) and Freiburg (131 km south-west). Two other listed cities lie within 100 km, and 14 within 300 km. The farthest listed city in Germany is Rostock, about 625 km north of Stuttgart.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Karlsruhe | 62 km north-west | 284,000 | moisture on terminals and corrosion |
| Mannheim | 94 km north-west | 308,000 | expansion and contraction loosening joints |
| Freiburg | 131 km south-west | 237,000 | moisture on terminals and corrosion |
| Augsburg | 135 km east | 301,000 | expansion and contraction loosening joints |
| Mainz | 148 km north-west | 223,000 | expansion and contraction loosening joints |
| Frankfurt am Main | 152 km north | 650,000 | moisture on terminals and corrosion |
A mid-sized city like Stuttgart may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
The sun and the clock in Stuttgart
Stuttgart keeps UTC+1, moving to UTC+2 while daylight saving applies.
Stuttgart lies at 48.8° N, 9.2° E. Daylight lasts about 16 h 10 min at the June solstice and about 8 h 15 min in December, with a noon sun 65° and 18° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. Stuttgart has a temperate climate, the same as the country as a whole, and 43 other listed cities share it.
Jobs in Stuttgart that call for capacitors
Typical work in Stuttgart that needs capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Condensing units for walk-in cold rooms
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Stuttgart
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Ask for the datasheet and the documents your project needs; in Germany that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.
Care and maintenance in Stuttgart
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check capacitors in Stuttgart. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A swollen, bulging or leaking case
Supply and delivery to Stuttgart
Shipments for Stuttgart normally clear customs at one of the main entry points of Germany and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Germany are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Stuttgart: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Stuttgart?
The mains supply in Germany is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Stuttgart?
To order capacitors for Stuttgart, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Stuttgart can I order for?
Enquiries are welcome from every part of Stuttgart. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Stuttgart?
Stuttgart keeps UTC+1, moving to UTC+2 while daylight saving applies. At 48.8° N there are about 16 h 10 min of daylight in June and about 8 h 15 min in December.
Which cities near Stuttgart can the same order serve?
The listed cities closest to Stuttgart are Karlsruhe (62 km north-west), Mannheim (94 km north-west) and Freiburg (131 km south-west). Combine them into one order and give each delivery address.
More Klima products for Stuttgart
- Klima Contactors in Stuttgart
- Klima Terminal Crimps in Stuttgart
- Klima Transformer for HVAC in Stuttgart
- Klima Flux Powder (100 g & 250 g) in Stuttgart
- Klima Filter Driers in Stuttgart
- Klima Pressure Switches (High & Low) in Stuttgart