Klima Industries

Capacitors for Wiesbaden

Wiesbaden is a mid-sized city in Germany. The climate is temperate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.

Capacitors are bought here mainly for offices, shops and malls as well as factories and workshops. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Wiesbaden.

Country
Germany
Population
289,000
Climate
Temperate
Coordinates
50.1° N, 8.2° E
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
From Berlin
450 km south-west
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Wiesbaden · Klima Capacitors overview

Capacitors and the climate in Wiesbaden

In Wiesbaden, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.

High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.

Capacitors in Wiesbaden and the cities near it

Wiesbaden ranks 23rd of the 44 listed cities in Germany and holds about 1.3% of the people living in them, roughly 8.4% of the size of the largest city, Berlin. From Berlin, the capital, Wiesbaden is roughly 450 km to the south-west. It is about the same size as Kabwe in Zambia, which has 289,000.

The closest are Mainz (12 km south), Frankfurt am Main (32 km east) and Mannheim (68 km south). Three other listed cities lie within 100 km, and 29 within 300 km. The farthest listed city in Germany is Rostock, about 518 km north-east of Wiesbaden.

CityDistancePeopleWhat wears capacitors first
Mainz12 km south223,000expansion and contraction loosening joints
Frankfurt am Main32 km east650,000moisture on terminals and corrosion
Mannheim68 km south308,000expansion and contraction loosening joints
Bonn109 km north-west331,000moisture on terminals and corrosion
Karlsruhe120 km south284,000moisture on terminals and corrosion
Saarbrucken130 km south-west183,000expansion and contraction loosening joints

A mid-sized city like Wiesbaden may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.

Daylight and sun angle in Wiesbaden

Wiesbaden keeps UTC+1, moving to UTC+2 while daylight saving applies.

Wiesbaden lies at 50.1° N, 8.2° E. Daylight lasts about 16 h 23 min at the June solstice and about 8 h 03 min in December, with a noon sun 63° and 16° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Wiesbaden is temperate, in line with the rest of Germany; 43 other listed cities share it.

Typical uses of capacitors in Wiesbaden

In Wiesbaden, these are the jobs that most often call for capacitors:

  • Fan coil unit and blower motors
  • Condensing units for walk-in cold rooms
  • Ventilation and exhaust fan motors

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Wiesbaden

  • Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
  • Confirm the supply first: Germany uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.

Keeping capacitors reliable in Wiesbaden

  • Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.

In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check capacitors in Wiesbaden. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Faults to watch for

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Ordering capacitors for Wiesbaden

To order capacitors for Wiesbaden, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Germany are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Capacitors in Wiesbaden: common questions

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

What voltage should capacitors be rated for in Wiesbaden?

The mains supply in Germany is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are capacitors delivered to Wiesbaden?

Shipments for Wiesbaden normally clear customs at one of the main entry points of Germany and finish the journey by road; send your delivery address with the enquiry.

Which parts of Wiesbaden can I order for?

Enquiries are welcome from every part of Wiesbaden. Send the delivery address with your enquiry.

Which cities near Wiesbaden can the same order serve?

The listed cities closest to Wiesbaden are Mainz (12 km south), Frankfurt am Main (32 km east) and Mannheim (68 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Wiesbaden?

Wiesbaden keeps UTC+1, moving to UTC+2 while daylight saving applies. At 50.1° N there are about 16 h 23 min of daylight in June and about 8 h 03 min in December.

More Klima products for Wiesbaden

Capacitors in cities near Wiesbaden