Klima Industries

Swedru: Klima Capacitors

Found in Ghana, Swedru is a smaller city with a hot and humid tropical climate. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Capacitors are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Swedru for a quotation.

Country
Ghana
Population
54,000
Climate
Hot and humid tropical
Coordinates
5.5° N, 0.7° W
Time zone
UTC+0 all year
From Accra
56 km west
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Swedru · Klima Capacitors overview

Conditions in Swedru that affect capacitors

In Swedru, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Capacitors in Swedru and the cities near it

Swedru ranks 27th of the 30 listed cities in Ghana and holds about 0.7% of the people living in them, roughly 2.1% of the size of the largest city, Kumasi. The capital, Accra, is about 56 km away, to the east of Swedru. For scale, Narva in Estonia has a similar population (54,000).

Nearest to Swedru: Winneba (22 km south), Buduburam (25 km east) and Atsiaman (45 km north-east). Nine other listed cities lie within 100 km, and 21 within 300 km. The farthest listed city in Ghana is Bawku, about 616 km north of Swedru.

CityDistancePeopleWhat wears capacitors first
Winneba22 km south71,000terminals loosening and parts running hot
Buduburam25 km east63,000terminals loosening and parts running hot
Atsiaman45 km north-east203,000terminals loosening and parts running hot
Akim Oda54 km north-west61,000moisture on terminals and corrosion
Accra56 km east2 millionterminals loosening and parts running hot
Suhum62 km north-east51,000terminals loosening and parts running hot

In a smaller city like Swedru, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

Daylight and sun angle in Swedru

Swedru keeps UTC+0 all year.

At 5.5° N, Swedru has about 12 h 27 min of daylight at the June solstice and about 11 h 48 min at the December solstice. The noon sun stands 72° above the horizon in June and 61° in December, and the sun climbs high in summer, so shade and ventilation around outdoor units matter. Swedru has a hot and humid tropical climate, the same as the country as a whole, and 29 other listed cities share it.

Typical uses of capacitors in Swedru

In Swedru, these are the jobs that most often call for capacitors:

  • Heat pump outdoor units
  • Split and window air conditioners
  • Condensing units for walk-in cold rooms

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting capacitors in Swedru

  • Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
  • For hot and humid tropical conditions in Swedru, favour sealed, corrosion-resistant construction.

Keeping capacitors reliable in Swedru

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.

A tropical climate keeps cooling demand steady through the year in Swedru, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Signs of trouble

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Supply and delivery to Swedru

Shipments for Swedru normally clear customs at one of the main entry points of Ghana and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Ghana are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Swedru: common questions

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

What voltage should capacitors be rated for in Swedru?

Ghana supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are capacitors delivered to Swedru?

To order capacitors for Swedru, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Swedru can I order for?

Enquiries are welcome from every part of Swedru. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Swedru?

Swedru keeps UTC+0 all year. At 5.5° N there are about 12 h 27 min of daylight in June and about 11 h 48 min in December.

Which cities near Swedru can the same order serve?

The listed cities closest to Swedru are Winneba (22 km south), Buduburam (25 km east) and Atsiaman (45 km north-east). Combine them into one order and give each delivery address.

More Klima products for Swedru

Capacitors in cities near Swedru