Buying capacitors in Lamia
With about 52,000 people, Lamia is a smaller city in Greece. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
The main users of capacitors in Lamia are offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Lamia.
- Country
- Greece
- Population
- 52,000
- Climate
- Mediterranean
- Coordinates
- 38.9° N, 22.4° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Athens
- 152 km north-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Lamia · Klima Capacitors overview
Capacitors and the climate in Lamia
In Lamia, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Where capacitors go from Lamia
Among the 21 listed cities in Greece, Lamia comes 17th by population, with about 2.2% of the listed urban population, roughly 7.8% of the size of the largest city, Athens. The capital, Athens, is about 152 km away, to the south-east of Lamia. For scale, Thomazeau in Haiti has a similar population (52,000).
Nearest to Lamia: Volos (69 km north-east), Larisa (81 km north) and Trikala (93 km north-west). Five other listed cities lie within 100 km, and 14 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Volos | 69 km north-east | 86,000 | terminals loosening and parts running hot |
| Larisa | 81 km north | 147,000 | expansion and contraction loosening joints |
| Trikala | 93 km north-west | 62,000 | expansion and contraction loosening joints |
| Agrinio | 94 km west | 47,000 | expansion and contraction loosening joints |
| Patra | 95 km south-west | 168,000 | terminals loosening and parts running hot |
| Chalkida | 112 km south-east | 59,000 | expansion and contraction loosening joints |
In a smaller city like Lamia, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Lamia
The clock in Lamia follows UTC+2, moving to UTC+3 while daylight saving applies.
At 38.9° N, Lamia has about 14 h 54 min of daylight at the June solstice and about 9 h 26 min at the December solstice. The noon sun stands 75° above the horizon in June and 28° in December, and the sun climbs high in summer, so shade and ventilation around outdoor units matter. Lamia has a Mediterranean climate, the same as the country as a whole, and 20 other listed cities share it.
Jobs in Lamia that call for capacitors
Capacitors are most often specified in Lamia for:
- Fan coil unit and blower motors
- Split and window air conditioners
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Lamia
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Confirm the supply first: Greece uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Lamia
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check capacitors in Lamia. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A swollen, bulging or leaking case
Supply and delivery to Lamia
Shipments for Lamia normally clear customs at one of the main entry points of Greece and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Greece are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Lamia: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Lamia?
The mains supply in Greece is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Lamia?
To order capacitors for Lamia, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Lamia can I order for?
Enquiries are welcome from every part of Lamia. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Lamia?
Lamia keeps UTC+2, moving to UTC+3 while daylight saving applies. At 38.9° N there are about 14 h 54 min of daylight in June and about 9 h 26 min in December.
Which cities near Lamia can the same order serve?
The listed cities closest to Lamia are Volos (69 km north-east), Larisa (81 km north) and Trikala (93 km north-west). Combine them into one order and give each delivery address.
More Klima products for Lamia
- Klima Contactors in Lamia
- Klima Terminal Crimps in Lamia
- Klima Transformer for HVAC in Lamia
- Klima Map Gas (Brazing & Welding) in Lamia
- Klima Thermostat Guards in Lamia
- Klima Copper Coils & Tubes in Lamia