Capacitors for Tocoa
Tocoa is a smaller city in Honduras. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Tocoa are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Tocoa are welcome.
- Country
- Honduras
- Population
- 112,000
- Climate
- Hot and humid tropical
- Coordinates
- 15.7° N, 86.0° W
- Time zone
- UTC-6 all year
- From Tegucigalpa
- 220 km north-east
- Supply
- 110 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Tocoa · Klima Capacitors overview
Conditions in Tocoa that affect capacitors
In Tocoa, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Where capacitors go from Tocoa
Among the 19 listed cities in Honduras, Tocoa comes 9th by population, with about 3.3% of the listed urban population, about 13% of the size of Tegucigalpa, the largest. Tocoa lies about 220 km north-east of Tegucigalpa, the capital. It is about the same size as Ballarat in Australia, which has 112,000.
Nearest to Tocoa: Sonaguera (36 km west), Olanchito (65 km west) and La Ceiba (84 km west). Four other listed cities lie within 100 km, and 17 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Sonaguera | 36 km west | 48,000 | moisture on terminals and corrosion |
| Olanchito | 65 km west | 124,000 | moisture on terminals and corrosion |
| La Ceiba | 84 km west | 222,000 | terminals loosening and parts running hot |
| Catacamas | 93 km south | 141,000 | terminals loosening and parts running hot |
| Teupasenti | 180 km south-west | 43,000 | moisture on terminals and corrosion |
| El Negrito | 187 km west | 51,000 | moisture on terminals and corrosion |
In a smaller city like Tocoa, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Tocoa
Local time in Tocoa is UTC-6 all year.
At 15.7° N, Tocoa has about 13 h 04 min of daylight at the June solstice and about 11 h 12 min at the December solstice. The noon sun stands 82° above the horizon in June and 51° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Tocoa is hot and humid tropical, in line with the rest of Honduras; 18 other listed cities share it.
Jobs in Tocoa that call for capacitors
Typical work in Tocoa that needs capacitors:
- Split and window air conditioners
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Tocoa
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: Honduras uses 110 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Tocoa
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
A tropical climate keeps cooling demand steady through the year in Tocoa, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Tocoa
Shipments for Tocoa normally clear customs at one of the main entry points of Honduras and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Honduras are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Tocoa: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Tocoa?
The supply in Honduras is 110 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.
How are capacitors delivered to Tocoa?
To order capacitors for Tocoa, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Tocoa can I order for?
Enquiries are welcome from every part of Tocoa. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Tocoa?
Tocoa keeps UTC-6 all year. At 15.7° N there are about 13 h 04 min of daylight in June and about 11 h 12 min in December.
Which cities near Tocoa can the same order serve?
The listed cities closest to Tocoa are Sonaguera (36 km west), Olanchito (65 km west) and La Ceiba (84 km west). Combine them into one order and give each delivery address.
More Klima products for Tocoa
- Klima Contactors in Tocoa
- Klima Terminal Crimps in Tocoa
- Klima Transformer for HVAC in Tocoa
- Klima Temperature Controllers in Tocoa
- Klima Cables (3 & 4 Core) in Tocoa
- Klima Thermostats in Tocoa