Capacitors for Kupang
Kupang is a mid-sized city in Indonesia. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for capacitors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Kupang.
- Country
- Indonesia
- Population
- 475,000
- Climate
- Hot and humid tropical
- Coordinates
- 10.2° S, 123.6° E
- Time zone
- UTC+8 all year
- From Jakarta
- 1,896 km east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Kupang · Klima Capacitors overview
What Kupang demands of capacitors
In Kupang, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Cities around Kupang that need capacitors
Kupang ranks 29th of the 60 listed cities in Indonesia and holds about 0.9% of the people living in them, roughly 5.6% of the size of the largest city, Jakarta. The capital, Jakarta, is about 1,896 km away, to the west of Kupang. It is about the same size as Skopje in North Macedonia, which has 475,000.
The closest are Kendari (699 km north), Makassar (723 km north-west) and Mataram (840 km west). No other listed city lies within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Kendari | 699 km north | 351,000 | terminals loosening and parts running hot |
| Makassar | 723 km north-west | 1.5 million | moisture on terminals and corrosion |
| Mataram | 840 km west | 441,000 | terminals loosening and parts running hot |
| Ambon | 879 km north-east | 347,000 | terminals loosening and parts running hot |
| Denpasar | 936 km west | 670,000 | moisture on terminals and corrosion |
| Situbondo | 1,089 km west | 686,000 | moisture on terminals and corrosion |
A mid-sized city like Kupang may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Time zone, sun and daylight in Kupang
The clock in Kupang follows UTC+8 all year. It is 1 hour ahead of Jakarta, which matters when you arrange a call or a delivery window.
Kupang lies at 10.2° S, 123.6° E. Daylight lasts about 11 h 32 min at the June solstice and about 12 h 43 min in December, with a noon sun 56° and 77° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Kupang is hot and humid tropical, in line with the rest of Indonesia; 59 other listed cities share it.
Jobs in Kupang that call for capacitors
Typical work in Kupang that needs capacitors:
- Chiller and air-cooled condenser fans
- Fan coil unit and blower motors
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Kupang
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- For hot and humid tropical conditions in Kupang, favour sealed, corrosion-resistant construction.
Care and maintenance in Kupang
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
A tropical climate keeps cooling demand steady through the year in Kupang, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A swollen, bulging or leaking case
Getting capacitors to Kupang
Shipments for Kupang normally clear customs at one of the main entry points of Indonesia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Indonesia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Kupang: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Kupang?
With a 230 V, 50 Hz supply, Indonesia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Kupang?
To order capacitors for Kupang, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Kupang can I order for?
Enquiries are welcome from every part of Kupang. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Kupang?
Kupang keeps UTC+8 all year. At 10.2° S there are about 11 h 32 min of daylight in June and about 12 h 43 min in December.
Which cities near Kupang can the same order serve?
The listed cities closest to Kupang are Kendari (699 km north), Makassar (723 km north-west) and Mataram (840 km west). Combine them into one order and give each delivery address.
More Klima products for Kupang
- Klima Contactors in Kupang
- Klima Terminal Crimps in Kupang
- Klima Transformer for HVAC in Kupang
- Klima Map Gas (Brazing & Welding) in Kupang
- Klima Cables (3 & 4 Core) in Kupang
- Klima Thermometers for HVAC in Kupang