Klima Industries

Klima Capacitors supplied to Clondalkin, Dublin

Clondalkin is an industrial area in Dublin, Ireland. Buyers here are mostly maintenance contractors, plant operators and workshops, who look for exact-match replacements, fast turnaround and trade quantities.

Demand for capacitors comes mostly from cold stores and food distribution. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Clondalkin, Dublin are welcome.

Area type
Industrial area
City
Dublin
Country
Ireland
Climate
Temperate
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Clondalkin, Dublin · Klima Capacitors overview

Conditions in Clondalkin, Dublin that affect capacitors

In Clondalkin, Dublin, cooling demand is seasonal, with short hot spells that stress equipment. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.

Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Clondalkin, Dublin at a glance

The directory names 10 areas in Dublin, among them Clondalkin, Docklands, Dun Laoghaire, Blanchardstown and Dublin Port. The city has about 1 million people, the national capital.

Industrial users in Clondalkin switch heavy motor loads many times a day, so contactors and capacitors need generous duty ratings and tight terminals, not just a matching nameplate.

Where Clondalkin fits in Dublin

Clondalkin is one of 10 areas listed for Dublin, and one of 6 classed as industrial areas. More industrial areas in Dublin, each with its own page, include Tallaght, Swords, Blanchardstown and Santry. The rest of the areas listed for Dublin are Docklands, Dublin Port, Dun Laoghaire and Sandyford.

Typical uses of capacitors in Clondalkin, Dublin

Typical work in Clondalkin, Dublin that needs capacitors:

  • Condensing units for walk-in cold rooms
  • Commercial display fridges and freezers
  • Packaged rooftop units and ducted systems

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting capacitors in Clondalkin, Dublin

  • Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
  • Ask for the datasheet and the documents your project needs; in Ireland that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.

Care and maintenance in Clondalkin, Dublin

  • Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.

Because Clondalkin, Dublin is in the northern hemisphere, the heaviest cooling load normally falls in July and August. Service capacitors in May or June, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Ordering capacitors for Clondalkin, Dublin

Deliveries for Clondalkin are arranged to Dublin; give a street address or a collection point in your enquiry.

National rules, standards and voltage for Ireland are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Capacitors in Clondalkin, Dublin: common questions

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

What voltage should capacitors be rated for in Clondalkin, Dublin?

Ireland supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are capacitors delivered to Clondalkin, Dublin?

Send the delivery address in Clondalkin, or a collection point in Dublin, together with the model and quantity you need.

What do buyers in Clondalkin usually need?

Clondalkin is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.

More Klima products for Clondalkin, Dublin

Capacitors in other areas of Dublin