Capacitors for Hadera
Hadera is a smaller city in Israel. The climate is Mediterranean. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Capacitors are bought here mainly for offices, shops and malls, homes and apartments as well as cold stores and food distribution. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Hadera for a quotation.
- Country
- Israel
- Population
- 97,000
- Climate
- Mediterranean
- Coordinates
- 32.4° N, 34.9° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Jerusalem
- 80 km north
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Hadera · Klima Capacitors overview
Conditions in Hadera that affect capacitors
In Hadera, cooling demand peaks from late spring to early autumn. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
Where capacitors go from Hadera
Among the 20 listed cities in Israel, Hadera comes 16th by population, with about 2.1% of the listed urban population, roughly 10% of the size of the largest city, Jerusalem. Hadera lies about 80 km north of Jerusalem, the capital. It is about the same size as Deventer in the Netherlands, which has 97,000.
Nearest to Hadera: Netanya (13 km south), Umm el Fahm (25 km east) and Kfar Saba (30 km south). 18 other listed cities lie within 100 km, and 19 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Netanya | 13 km south | 228,000 | expansion and contraction loosening joints |
| Umm el Fahm | 25 km east | 56,000 | expansion and contraction loosening joints |
| Kfar Saba | 30 km south | 110,000 | terminals loosening and parts running hot |
| Petah Tiqva | 39 km south | 254,000 | expansion and contraction loosening joints |
| Bnei Brak | 41 km south | 214,000 | expansion and contraction loosening joints |
| Haifa | 42 km north | 285,000 | terminals loosening and parts running hot |
In a smaller city like Hadera, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Hadera
Local time in Hadera is UTC+2, moving to UTC+3 while daylight saving applies.
At 32.4° N, Hadera has about 14 h 17 min of daylight at the June solstice and about 10 h 01 min at the December solstice. The noon sun stands 81° above the horizon in June and 34° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Hadera is Mediterranean, in line with the rest of Israel; 19 other listed cities share it.
Where capacitors are used in Hadera
Capacitors are most often specified in Hadera for:
- Condensing units for walk-in cold rooms
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Hadera
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Israel uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Hadera
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
Because Hadera is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service capacitors in April or May, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Hadera
To order capacitors for Hadera, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Israel are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Hadera: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Hadera?
With a 230 V, 50 Hz supply, Israel follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Hadera?
Shipments for Hadera normally clear customs at one of the main entry points of Israel and finish the journey by road; send your delivery address with the enquiry.
Which parts of Hadera can I order for?
Enquiries are welcome from every part of Hadera. Send the delivery address with your enquiry.
Which cities near Hadera can the same order serve?
The listed cities closest to Hadera are Netanya (13 km south), Umm el Fahm (25 km east) and Kfar Saba (30 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Hadera?
Hadera keeps UTC+2, moving to UTC+3 while daylight saving applies. At 32.4° N there are about 14 h 17 min of daylight in June and about 10 h 01 min in December.
More Klima products for Hadera
- Klima Contactors in Hadera
- Klima Terminal Crimps in Hadera
- Klima Transformer for HVAC in Hadera
- Klima Delay on Make Timer in Hadera
- Klima Temperature Controllers in Hadera
- Klima PVC Tapes in Hadera