Agboville: Klima Capacitors
Found in Ivory Coast, Agboville is a smaller city with a hot and humid tropical climate. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for capacitors comes mostly from offices, shops and malls as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Agboville are welcome.
- Country
- Ivory Coast
- Population
- 82,000
- Climate
- Hot and humid tropical
- Coordinates
- 5.9° N, 4.2° W
- Time zone
- UTC+0 all year
- From Yamoussoukro
- 154 km south-east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Agboville · Klima Capacitors overview
Capacitors and the climate in Agboville
In Agboville, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Where capacitors go from Agboville
Among the 28 listed cities in Ivory Coast, Agboville comes 22nd by population, with about 0.7% of the listed urban population, roughly 1.3% of the size of the largest city, Abidjan. From Yamoussoukro, the capital, Agboville is roughly 154 km to the south-east. For scale, Qal'at Bishah in Saudi Arabia has a similar population (82,000).
Nearest to Agboville: Adzope (44 km north-east), Abidjan (68 km south) and Dabou (69 km south). Five other listed cities lie within 100 km, and 21 within 300 km. The farthest listed city in Ivory Coast is Danane, about 460 km west of Agboville.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Adzope | 44 km north-east | 76,000 | moisture on terminals and corrosion |
| Abidjan | 68 km south | 6.3 million | terminals loosening and parts running hot |
| Dabou | 69 km south | 138,000 | moisture on terminals and corrosion |
| Grand-Bassam | 95 km south-east | 97,000 | terminals loosening and parts running hot |
| Dimbokro | 97 km north-west | 70,000 | terminals loosening and parts running hot |
| Abengourou | 119 km north-east | 131,000 | moisture on terminals and corrosion |
In a smaller city like Agboville, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Agboville
The clock in Agboville follows UTC+0 all year.
At 5.9° N, Agboville has about 12 h 28 min of daylight at the June solstice and about 11 h 47 min at the December solstice. The noon sun stands 72° above the horizon in June and 61° in December, and the sun climbs high in summer, so shade and ventilation around outdoor units matter. Agboville has a hot and humid tropical climate, the same as the country as a whole, and 27 other listed cities share it.
Jobs in Agboville that call for capacitors
In Agboville, these are the jobs that most often call for capacitors:
- Condensing units for walk-in cold rooms
- Fan coil unit and blower motors
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Agboville
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Ask for the datasheet and the documents your project needs; in Ivory Coast that usually means CODINORM (national standards body) requirements.
Keeping capacitors reliable in Agboville
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
A tropical climate keeps cooling demand steady through the year in Agboville, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A swollen, bulging or leaking case
Ordering capacitors for Agboville
To order capacitors for Agboville, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Ivory Coast are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Agboville
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Agboville?
Ivory Coast supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Agboville?
Shipments for Agboville normally clear customs at one of the main entry points of Ivory Coast and finish the journey by road; send your delivery address with the enquiry.
Which parts of Agboville can I order for?
Enquiries are welcome from every part of Agboville. Send the delivery address with your enquiry.
Which cities near Agboville can the same order serve?
The listed cities closest to Agboville are Adzope (44 km north-east), Abidjan (68 km south) and Dabou (69 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Agboville?
Agboville keeps UTC+0 all year. At 5.9° N there are about 12 h 28 min of daylight in June and about 11 h 47 min in December.
More Klima products for Agboville
- Klima Contactors in Agboville
- Klima Terminal Crimps in Agboville
- Klima Transformer for HVAC in Agboville
- Klima Copper Coils & Tubes in Agboville
- Klima Cables (3 & 4 Core) in Agboville
- Klima Pressure Switches (High & Low) in Agboville