Klima Industries

Klima capacitors for Old Harbour

Found in Jamaica, Old Harbour is a smaller city with a hot and humid tropical climate. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of capacitors in Old Harbour are offices, shops and malls as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Old Harbour are welcome.

Country
Jamaica
Population
26,000
Climate
Hot and humid tropical
Coordinates
17.9° N, 77.1° W
Time zone
UTC-5 all year
From Kingston
34 km west
Supply
110 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Old Harbour · Klima Capacitors overview

What Old Harbour demands of capacitors

In Old Harbour, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.

Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Cities around Old Harbour that need capacitors

Old Harbour ranks 8th of the 10 listed cities in Jamaica and holds about 1.3% of the people living in them, roughly 2.8% of the size of the largest city, Kingston. Old Harbour lies about 34 km west of Kingston, the capital. For scale, Nggosi in the Solomon Islands has a similar population (26,000).

The closest are May Pen (15 km west), Spanish Town (17 km east) and Linstead (23 km north). Seven other listed cities lie within 100 km, and nine within 300 km. The farthest listed city in Jamaica is Savanna-la-Mar, about 113 km west of Old Harbour.

CityDistancePeopleWhat wears capacitors first
May Pen15 km west45,000moisture on terminals and corrosion
Spanish Town17 km east145,000terminals loosening and parts running hot
Linstead23 km north21,000moisture on terminals and corrosion
Kingston34 km east938,000moisture on terminals and corrosion
New Kingston35 km east584,000terminals loosening and parts running hot
Mandeville44 km west47,000moisture on terminals and corrosion

In a smaller city like Old Harbour, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

The sun and the clock in Old Harbour

The clock in Old Harbour follows UTC-5 all year.

Sunlight at 17.9° N (Old Harbour): about 13 h 12 min of daylight in June, about 11 h 03 min in December, and a noon sun that reaches 85° in June and 49° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Old Harbour has a hot and humid tropical climate, the same as the country as a whole, and 9 other listed cities share it.

Where capacitors are used in Old Harbour

Typical work in Old Harbour that needs capacitors:

  • Fan coil unit and blower motors
  • Heat pump outdoor units
  • Split and window air conditioners

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick capacitors for work in Old Harbour

  • Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
  • For hot and humid tropical conditions in Old Harbour, favour sealed, corrosion-resistant construction.

Care and maintenance in Old Harbour

  • Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.

A tropical climate keeps cooling demand steady through the year in Old Harbour, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • Repeated overload trips, high running current or a unit that cuts out on hot afternoons

Getting capacitors to Old Harbour

To order capacitors for Old Harbour, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Jamaica are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Old Harbour: common questions

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

What voltage should capacitors be rated for in Old Harbour?

The supply in Jamaica is 110 V, 50 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a capacitor.

How are capacitors delivered to Old Harbour?

Shipments for Old Harbour normally clear customs at one of the main entry points of Jamaica and finish the journey by road; send your delivery address with the enquiry.

Which parts of Old Harbour can I order for?

Enquiries are welcome from every part of Old Harbour. Send the delivery address with your enquiry.

Which cities near Old Harbour can the same order serve?

The listed cities closest to Old Harbour are May Pen (15 km west), Spanish Town (17 km east) and Linstead (23 km north). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Old Harbour?

Old Harbour keeps UTC-5 all year. At 17.9° N there are about 13 h 12 min of daylight in June and about 11 h 03 min in December.

More Klima products for Old Harbour

Capacitors in cities near Old Harbour