Klima Capacitors in Kashiwa
Kashiwa is a mid-sized city in Japan. The climate is humid subtropical. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
The main users of capacitors in Kashiwa are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Kashiwa are welcome.
- Country
- Japan
- Population
- 433,000
- Climate
- Humid subtropical
- Coordinates
- 35.9° N, 140.0° E
- Time zone
- UTC+9 all year
- From Tokyo
- 32 km north-east
- Supply
- 100 V, 50/60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Kashiwa · Klima Capacitors overview
What Kashiwa demands of capacitors
In Kashiwa, cooling demand peaks through a long, humid summer. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Capacitors in Kashiwa and the cities near it
Kashiwa ranks 35th of the 53 listed cities in Japan and holds about 0.8% of the people living in them, about 4.5% of the size of Tokyo, the largest. The capital, Tokyo, is about 32 km away, to the south-west of Kashiwa. It is about the same size as Ogbomoso in Nigeria, which has 433,000.
Nearest to Kashiwa: Honcho (18 km south), Saitama (29 km west) and Chiba (32 km south-east). 14 other listed cities lie within 100 km, and 28 within 300 km. At the other extreme, Kagoshima is about 994 km south-west of Kashiwa, the furthest listed city in Japan.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Honcho | 18 km south | 645,000 | moisture on terminals and corrosion |
| Saitama | 29 km west | 1.3 million | terminals loosening and parts running hot |
| Chiba | 32 km south-east | 980,000 | moisture on terminals and corrosion |
| Tokyo | 32 km south-west | 9.7 million | moisture on terminals and corrosion |
| Kawasaki | 45 km south-west | 1.5 million | moisture on terminals and corrosion |
| Suginami | 47 km north-east | 588,000 | terminals loosening and parts running hot |
A mid-sized city like Kashiwa may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
The sun and the clock in Kashiwa
The clock in Kashiwa follows UTC+9 all year.
Kashiwa lies at 35.9° N, 140.0° E. Daylight lasts about 14 h 36 min at the June solstice and about 9 h 43 min in December, with a noon sun 78° and 31° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Kashiwa is humid subtropical, in line with the rest of Japan; 51 other listed cities share it.
Where capacitors are used in Kashiwa
In Kashiwa, these are the jobs that most often call for capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Kashiwa
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: Japan uses 100 V at 50/60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Kashiwa
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Kashiwa lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of capacitors for April or May, ahead of that peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Supply and delivery to Kashiwa
To order capacitors for Kashiwa, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Japan are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Kashiwa: common questions
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in Kashiwa?
The supply in Japan is 100 V and the grid frequency differs between the east and the west, so confirm both the voltage and the frequency when you choose a capacitor.
How are capacitors delivered to Kashiwa?
Shipments for Kashiwa normally clear customs at one of the main entry points of Japan and finish the journey by road; send your delivery address with the enquiry.
Which parts of Kashiwa can I order for?
Enquiries are welcome from every part of Kashiwa. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Kashiwa?
Kashiwa keeps UTC+9 all year. At 35.9° N there are about 14 h 36 min of daylight in June and about 9 h 43 min in December.
Which cities near Kashiwa can the same order serve?
The listed cities closest to Kashiwa are Honcho (18 km south), Saitama (29 km west) and Chiba (32 km south-east). Combine them into one order and give each delivery address.
More Klima products for Kashiwa
- Klima Contactors in Kashiwa
- Klima Terminal Crimps in Kashiwa
- Klima Transformer for HVAC in Kashiwa
- Klima Thermostats in Kashiwa
- Klima Filter Driers in Kashiwa
- Klima Delay on Make Timer in Kashiwa