Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Bsharri · Klima Capacitors overview
Conditions in Bsharri that affect capacitors
In Bsharri, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
Where capacitors go from Bsharri
Bsharri ranks 15th of the 15 listed cities in Lebanon and holds about 0.5% of the people living in them, roughly 1% of the size of the largest city, Beirut. From Beirut, the capital, Bsharri is roughly 61 km to the north-east. It is about the same size as Castries in St Lucia, which has 20,000.
The closest are Tripoli (25 km north-west), Chmistar (32 km south) and Baalbek (33 km south-east). 10 other listed cities lie within 100 km, and 14 within 300 km. The farthest listed city in Lebanon is En Naqoura, about 150 km south-west of Bsharri.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Tripoli | 25 km north-west | 229,000 | terminals loosening and parts running hot |
| Chmistar | 32 km south | 30,000 | terminals loosening and parts running hot |
| Baalbek | 33 km south-east | 31,000 | terminals loosening and parts running hot |
| Byblos | 36 km south-west | 21,000 | terminals loosening and parts running hot |
| El Hermel | 38 km north-east | 22,000 | terminals loosening and parts running hot |
| Aarsal | 39 km east | 50,000 | expansion and contraction loosening joints |
In a smaller city like Bsharri, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Bsharri
Bsharri keeps UTC+2, moving to UTC+3 while daylight saving applies.
Bsharri lies at 34.3° N, 36.0° E. Daylight lasts about 14 h 27 min at the June solstice and about 9 h 52 min in December, with a noon sun 79° and 32° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Bsharri is Mediterranean, in line with the rest of Lebanon; 14 other listed cities share it.
Jobs in Bsharri that call for capacitors
Capacitors are most often specified in Bsharri for:
- Fan coil unit and blower motors
- Heat pump outdoor units
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Bsharri
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- For Mediterranean conditions in Bsharri, favour higher temperature ratings and some margin on every rated value.
Keeping capacitors reliable in Bsharri
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Because Bsharri is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service capacitors in April or May, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A swollen, bulging or leaking case
Ordering capacitors for Bsharri
To order capacitors for Bsharri, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Lebanon are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Bsharri
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Bsharri?
Lebanon supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Bsharri?
Shipments for Bsharri normally clear customs at one of the main entry points of Lebanon and finish the journey by road; send your delivery address with the enquiry.
Which parts of Bsharri can I order for?
Enquiries are welcome from every part of Bsharri. Send the delivery address with your enquiry.
Which cities near Bsharri can the same order serve?
The listed cities closest to Bsharri are Tripoli (25 km north-west), Chmistar (32 km south) and Baalbek (33 km south-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Bsharri?
Bsharri keeps UTC+2, moving to UTC+3 while daylight saving applies. At 34.3° N there are about 14 h 27 min of daylight in June and about 9 h 52 min in December.
More Klima products for Bsharri
- Klima Contactors in Bsharri
- Klima Terminal Crimps in Bsharri
- Klima Transformer for HVAC in Bsharri
- Klima Filter Driers in Bsharri
- Klima Drier Core 48-KL in Bsharri
- Klima Delay on Make Timer in Bsharri