Klima Capacitors in Benghazi
With about 757,000 people, Benghazi is a mid-sized city in Libya. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
The main users of capacitors in Benghazi are offices, shops and malls as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Benghazi.
- Country
- Libya
- Population
- 757,000
- Climate
- Hot and arid
- Coordinates
- 32.1° N, 20.1° E
- Time zone
- UTC+2 all year
- From Tripoli
- 651 km east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Benghazi · Klima Capacitors overview
What Benghazi demands of capacitors
In Benghazi, air conditioning and refrigeration run for most of the year. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Fine dust settles on capacitors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
Where capacitors go from Benghazi
Benghazi ranks 2nd of the 18 listed cities in Libya and holds about 17% of the people living in them, roughly 58% of the size of the largest city, Tripoli. Benghazi lies about 651 km east of Tripoli, the capital. It is about the same size as Ipoh in Malaysia, which has 760,000.
In the directory the nearest cities are Al Marj (83 km north-east), Ajdabiya (152 km south) and Al Bayda' (174 km north-east). One other listed city lies within 100 km, and four within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Al Marj | 83 km north-east | 85,000 | terminals loosening and parts running hot |
| Ajdabiya | 152 km south | 132,000 | terminals loosening and parts running hot |
| Al Bayda' | 174 km north-east | 129,000 | terminals loosening and parts running hot |
| Darnah | 252 km east | 103,000 | dust on contacts and blocked cooling |
| Sirte | 344 km west | 107,000 | dust on contacts and blocked cooling |
| Tobruk | 366 km east | 141,000 | terminals loosening and parts running hot |
A mid-sized city like Benghazi may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Daylight and sun angle in Benghazi
Local time in Benghazi is UTC+2 all year.
At 32.1° N, Benghazi has about 14 h 15 min of daylight at the June solstice and about 10 h 03 min at the December solstice. The noon sun stands 81° above the horizon in June and 34° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Benghazi is hot and arid, in line with the rest of Libya; 17 other listed cities share it.
Jobs in Benghazi that call for capacitors
Typical work in Benghazi that needs capacitors:
- Heat pump outdoor units
- Split and window air conditioners
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Benghazi
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- Ask for the datasheet and the documents your project needs; in Libya that usually means LNCSM (Libyan National Centre for Standardization and Metrology) requirements.
Keeping capacitors reliable in Benghazi
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Benghazi is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service capacitors in March or April, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A humming compressor that fails to start, or a fan that has to be spun by hand
Ordering capacitors for Benghazi
To order capacitors for Benghazi, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Libya are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Benghazi: common questions
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Benghazi?
The mains supply in Libya is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Benghazi?
Shipments for Benghazi normally clear customs at one of the main entry points of Libya and finish the journey by road; send your delivery address with the enquiry.
Which parts of Benghazi can I order for?
Enquiries are welcome from every part of Benghazi. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Benghazi?
Benghazi keeps UTC+2 all year. At 32.1° N there are about 14 h 15 min of daylight in June and about 10 h 03 min in December.
Which cities near Benghazi can the same order serve?
The listed cities closest to Benghazi are Al Marj (83 km north-east), Ajdabiya (152 km south) and Al Bayda' (174 km north-east). Combine them into one order and give each delivery address.
More Klima products for Benghazi
- Klima Contactors in Benghazi
- Klima Terminal Crimps in Benghazi
- Klima Transformer for HVAC in Benghazi
- Klima Copper Coils & Tubes in Benghazi
- Klima Thermostats in Benghazi
- Klima Delay on Make Timer in Benghazi