Capacitors supply in Tetouan
Tetouan is a mid-sized city in Morocco. The climate is Mediterranean. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Demand for capacitors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Tetouan.
- Country
- Morocco
- Population
- 416,000
- Climate
- Mediterranean
- Coordinates
- 35.6° N, 5.4° W
- Time zone
- UTC+1 all year
- From Rabat
- 219 km north-east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Tetouan · Klima Capacitors overview
Conditions in Tetouan that affect capacitors
In Tetouan, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Capacitors in Tetouan and the cities near it
By population Tetouan is 11th of the 32 cities listed for Morocco, with roughly 2.7% of their combined population, about 11% of the size of Casablanca, the largest. From Rabat, the capital, Tetouan is roughly 219 km to the north-east. For scale, Toyama in Japan has a similar population (416,000).
Nearest to Tetouan: Tangier (44 km north-west), Ksar El Kebir (81 km south-west) and Larache (83 km south-west). Three other listed cities lie within 100 km, and 16 within 300 km. At the other extreme, Guelmim is about 855 km south-west of Tetouan, the furthest listed city in Morocco.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Tangier | 44 km north-west | 1 million | expansion and contraction loosening joints |
| Ksar El Kebir | 81 km south-west | 138,000 | terminals loosening and parts running hot |
| Larache | 83 km south-west | 137,000 | terminals loosening and parts running hot |
| Al Hoceima | 135 km east | 396,000 | terminals loosening and parts running hot |
| Sidi Slimane | 155 km south | 102,000 | terminals loosening and parts running hot |
| Fes | 175 km south | 1.2 million | expansion and contraction loosening joints |
A mid-sized city like Tetouan may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Time zone, sun and daylight in Tetouan
The clock in Tetouan follows UTC+1 all year.
At 35.6° N, Tetouan has about 14 h 34 min of daylight at the June solstice and about 9 h 45 min at the December solstice. The noon sun stands 78° above the horizon in June and 31° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Tetouan has a Mediterranean climate, the same as the country as a whole, and 26 other listed cities share it.
Typical uses of capacitors in Tetouan
In Tetouan, these are the jobs that most often call for capacitors:
- Fan coil unit and blower motors
- Ventilation and exhaust fan motors
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Tetouan
- Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
- For Mediterranean conditions in Tetouan, favour higher temperature ratings and some margin on every rated value.
Care and maintenance in Tetouan
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Tetouan lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of capacitors for April or May, ahead of that peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Tetouan
To order capacitors for Tetouan, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Morocco are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Tetouan
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Tetouan?
With a 230 V, 50 Hz supply, Morocco follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Tetouan?
Shipments for Tetouan normally clear customs at one of the main entry points of Morocco and finish the journey by road; send your delivery address with the enquiry.
Which parts of Tetouan can I order for?
Enquiries are welcome from every part of Tetouan. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Tetouan?
Tetouan keeps UTC+1 all year. At 35.6° N there are about 14 h 34 min of daylight in June and about 9 h 45 min in December.
Which cities near Tetouan can the same order serve?
The listed cities closest to Tetouan are Tangier (44 km north-west), Ksar El Kebir (81 km south-west) and Larache (83 km south-west). Combine them into one order and give each delivery address.
More Klima products for Tetouan
- Klima Contactors in Tetouan
- Klima Terminal Crimps in Tetouan
- Klima Transformer for HVAC in Tetouan
- Klima Thermometers for HVAC in Tetouan
- Klima Thermostat Guards in Tetouan
- Klima Drier Core 48-KL in Tetouan