Moss: Klima Capacitors
Found in Norway, Moss is a smaller city with a cold climate. Summers are short and mild, and winters are long and often well below freezing.
Demand for capacitors comes mostly from offices, shops and malls, homes and apartments as well as cold stores and food distribution. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Moss.
- Country
- Norway
- Population
- 50,000
- Climate
- Cold
- Coordinates
- 59.4° N, 10.7° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Oslo
- 53 km south
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Moss · Klima Capacitors overview
Capacitors and the climate in Moss
In Moss, cooling is mostly for process, commercial and cold-chain needs rather than comfort. Low temperatures make plastics brittle and slow some electrical parts; let cold capacitors warm up before fitting where you can, and never force a terminal.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Cities around Moss that need capacitors
By population Moss is 14th of the 17 cities listed for Norway, with roughly 1.9% of their combined population, about 4.6% of the size of Oslo, the largest. Moss lies about 53 km south of Oslo, the capital. For scale, Rwamwanja Refugee Camp in Uganda has a similar population (50,000).
The closest are Tonsberg (23 km south-west), Fredrikstad (29 km south-east) and Sarpsborg (31 km south-east). Eight other listed cities lie within 100 km, and 11 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Tonsberg | 23 km south-west | 55,000 | brittle insulation and hard starting |
| Fredrikstad | 29 km south-east | 84,000 | brittle insulation and hard starting |
| Sarpsborg | 31 km south-east | 59,000 | expansion and contraction loosening joints |
| Sandefjord | 42 km south-west | 64,000 | expansion and contraction loosening joints |
| Drammen | 43 km north-west | 106,000 | brittle insulation and hard starting |
| Oslo | 53 km north | 1.1 million | expansion and contraction loosening joints |
In a smaller city like Moss, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Moss
Moss keeps UTC+1, moving to UTC+2 while daylight saving applies.
Sunlight at 59.4° N (Moss): about 18 h 39 min of daylight in June, about 6 h 03 min in December, and a noon sun that reaches 54° in June and 7° in December. The sun never climbs very high, so cold, wind and snow load on outdoor units matter more than direct heat. Moss has a cold climate, the same as the country as a whole, and 16 other listed cities share it.
Typical uses of capacitors in Moss
In Moss, these are the jobs that most often call for capacitors:
- Chiller and air-cooled condenser fans
- Split and window air conditioners
- Condensing units for walk-in cold rooms
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Moss
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Confirm the supply first: Norway uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Moss
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
The warm season in Moss is short, normally from June to August, while refrigeration and heating work through the cold months. Check capacitors in April or May and again before winter. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Supply and delivery to Moss
Shipments for Moss normally clear customs at one of the main entry points of Norway and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Norway are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Moss
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Moss?
The mains supply in Norway is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Moss?
To order capacitors for Moss, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Moss can I order for?
Enquiries are welcome from every part of Moss. Send the delivery address with your enquiry.
Which cities near Moss can the same order serve?
The listed cities closest to Moss are Tonsberg (23 km south-west), Fredrikstad (29 km south-east) and Sarpsborg (31 km south-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Moss?
Moss keeps UTC+1, moving to UTC+2 while daylight saving applies. At 59.4° N there are about 18 h 39 min of daylight in June and about 6 h 03 min in December.
More Klima products for Moss
- Klima Contactors in Moss
- Klima Terminal Crimps in Moss
- Klima Transformer for HVAC in Moss
- Klima Filter Driers in Moss
- Klima Flux Powder (100 g & 250 g) in Moss
- Klima Drier Core 48-KL in Moss