Mokotow, Warsaw: Klima Capacitors
Mokotow is a central business district in Warsaw, Poland. Typical customers are facilities managers and building-services contractors, and what they want is parts for high-rise plant rooms, chillers and fan coil units.
Capacitors are bought here mainly for offices, shops and malls, hospitals and clinics as well as data centres and server rooms. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Mokotow, Warsaw for a quotation.
- Area type
- Central business district
- City
- Warsaw
- Country
- Poland
- Climate
- Continental
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Mokotow, Warsaw · Klima Capacitors overview
Conditions in Mokotow, Warsaw that affect capacitors
In Mokotow, Warsaw, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
Mokotow, Warsaw at a glance
Mokotow is one of 9 areas listed for Warsaw; others include Wola, Bemowo, Ursynow and Praga. Warsaw has about 1.7 million people, the national capital.
High-rise plant rooms in Mokotow run large fan coil units and chillers, so check coil voltages, contactor ratings and the capacitors on the many fan motors.
Where Mokotow fits in Warsaw
Mokotow is one of 9 areas listed for Warsaw, and one of 2 classed as central business districts. Other central business districts in Warsaw include Wola. The rest of the areas listed for Warsaw are Ursus, Bemowo, Targowek, Praga and Bialoleka.
Jobs in Mokotow, Warsaw that call for capacitors
Typical work in Mokotow, Warsaw that needs capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Condensing units for walk-in cold rooms
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Mokotow, Warsaw
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Confirm the supply first: Poland uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Mokotow, Warsaw
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check capacitors in Mokotow, Warsaw. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A swollen, bulging or leaking case
Getting capacitors to Mokotow, Warsaw
Deliveries for Mokotow are arranged to Warsaw; give a street address or a collection point in your enquiry.
National rules, standards and voltage for Poland are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Mokotow, Warsaw: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Mokotow, Warsaw?
With a 230 V, 50 Hz supply, Poland follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Mokotow, Warsaw?
Send the delivery address in Mokotow, or a collection point in Warsaw, together with the model and quantity you need.
What do buyers in Mokotow usually need?
Mokotow is a central business district, so the buyers are mostly facilities managers and building-services contractors. They want parts for high-rise plant rooms, chillers and fan coil units.
More Klima products for Mokotow, Warsaw
- Klima Contactors in Mokotow, Warsaw
- Klima Terminal Crimps in Mokotow, Warsaw
- Klima Transformer for HVAC in Mokotow, Warsaw
- Klima Condensate Pump in Mokotow, Warsaw
- Klima Delay on Make Timer in Mokotow, Warsaw
- Klima Thermostats in Mokotow, Warsaw