Klima Industries

Klima Capacitors supplied to Az Za'ayin

With about 54,000 people, Az Za'ayin is a smaller city in Qatar. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

The main users of capacitors in Az Za'ayin are offices, shops and malls as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Az Za'ayin.

Country
Qatar
Population
54,000
Climate
Hot and arid
Coordinates
25.6° N, 51.5° E
Time zone
UTC+3 all year
From Doha
33 km north
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Az Za'ayin · Klima Capacitors overview

Conditions in Az Za'ayin that affect capacitors

In Az Za'ayin, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Fine dust settles on capacitors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.

Where capacitors go from Az Za'ayin

Among the 5 listed cities in Qatar, Az Za'ayin comes 4th by population, with about 6% of the listed urban population, roughly 16% of the size of the largest city, Doha. Az Za'ayin lies about 33 km north of Doha, the capital. For scale, Bahla' in Oman has a similar population (54,000).

In the directory the nearest cities are Lusail (18 km south), Al Rayyan (32 km south) and Doha (33 km south). Four other listed cities lie within 100 km, and four within 300 km.

CityDistancePeopleWhat wears capacitors first
Lusail18 km south199,000dust on contacts and blocked cooling
Al Rayyan32 km south272,000terminals loosening and parts running hot
Doha33 km south345,000terminals loosening and parts running hot
Umm Ghuwaylinah33 km west39,000dust on contacts and blocked cooling

In a smaller city like Az Za'ayin, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

Time zone, sun and daylight in Az Za'ayin

Az Za'ayin keeps UTC+3 all year.

At 25.6° N, Az Za'ayin has about 13 h 44 min of daylight at the June solstice and about 10 h 32 min at the December solstice. The noon sun stands 88° above the horizon in June and 41° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Az Za'ayin has a hot and arid climate, the same as the country as a whole, and 4 other listed cities share it.

Where capacitors are used in Az Za'ayin

In Az Za'ayin, these are the jobs that most often call for capacitors:

  • Fan coil unit and blower motors
  • Condensing units for walk-in cold rooms
  • Heat pump outdoor units

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Az Za'ayin

  • Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
  • For hot and arid conditions in Az Za'ayin, favour higher temperature ratings and some margin on every rated value.

Keeping capacitors reliable in Az Za'ayin

  • Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.

In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check capacitors in Az Za'ayin. Electrical parts fail most often when the load is highest, so retighten and test before the peak.

Signs of trouble

  • Repeated overload trips, high running current or a unit that cuts out on hot afternoons

Supply and delivery to Az Za'ayin

To order capacitors for Az Za'ayin, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Qatar are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about capacitors in Az Za'ayin

Are run capacitors polarised?

No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.

What voltage should capacitors be rated for in Az Za'ayin?

With a 230 V, 50 Hz supply, Qatar follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.

How are capacitors delivered to Az Za'ayin?

Shipments for Az Za'ayin normally clear customs at one of the main entry points of Qatar and finish the journey by road; send your delivery address with the enquiry.

Which parts of Az Za'ayin can I order for?

Enquiries are welcome from every part of Az Za'ayin. Send the delivery address with your enquiry.

Which cities near Az Za'ayin can the same order serve?

The listed cities closest to Az Za'ayin are Lusail (18 km south), Al Rayyan (32 km south) and Doha (33 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Az Za'ayin?

Az Za'ayin keeps UTC+3 all year. At 25.6° N there are about 13 h 44 min of daylight in June and about 10 h 32 min in December.