Buying capacitors in Apia
Apia is the capital of Samoa and a smaller city. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for capacitors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Apia are welcome.
- Country
- Samoa
- Population
- 40,000
- Climate
- Hot and humid tropical
- Coordinates
- 13.8° S, 171.8° W
- Time zone
- UTC+13 all year
- Supply
- 230 V, 50 Hz
- Status
- National capital
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Apia · Klima Capacitors overview
Capacitors and the climate in Apia
In Apia, cooling and refrigeration work in every month of the year. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Where capacitors go from Apia
For scale, Garango in Burkina Faso has a similar population (40,000).
In a smaller city like Apia, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Apia
The clock in Apia follows UTC+13 all year.
Apia lies at 13.8° S, 171.8° W. Daylight lasts about 11 h 18 min at the June solstice and about 12 h 57 min in December, with a noon sun 53° and 80° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.
Where capacitors are used in Apia
In Apia, these are the jobs that most often call for capacitors:
- Split and window air conditioners
- Heat pump outdoor units
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Apia
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- For hot and humid tropical conditions in Apia, favour sealed, corrosion-resistant construction.
Keeping capacitors reliable in Apia
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
With little seasonal change in temperature, air conditioning in Apia works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Ordering capacitors for Apia
To order capacitors for Apia, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Samoa are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Apia: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Apia?
With a 230 V, 50 Hz supply, Samoa follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Apia?
Shipments for Apia normally clear customs at one of the main entry points of Samoa and finish the journey by road; send your delivery address with the enquiry.
Which parts of Apia can I order for?
Enquiries are welcome from every part of Apia. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Apia?
Apia keeps UTC+13 all year. At 13.8° S there are about 11 h 18 min of daylight in June and about 12 h 57 min in December.