Klima Capacitors in Uzice
With about 64,000 people, Uzice is a smaller city in Serbia. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Capacitors are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Uzice.
- Country
- Serbia
- Population
- 64,000
- Climate
- Continental
- Coordinates
- 43.9° N, 19.8° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Belgrade
- 116 km south-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Uzice · Klima Capacitors overview
Conditions in Uzice that affect capacitors
In Uzice, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
Low temperatures make plastics brittle and slow some electrical parts; let cold capacitors warm up before fitting where you can, and never force a terminal.
Cities around Uzice that need capacitors
Among the 19 listed cities in Serbia, Uzice comes 12th by population, with about 2.1% of the listed urban population, about 5% of the size of Belgrade, the largest. Uzice lies about 116 km south-west of Belgrade, the capital. For scale, New Halfa in Sudan has a similar population (64,000).
Nearest to Uzice: Cacak (40 km east), Valjevo (46 km north) and Kraljevo (69 km east). Seven other listed cities lie within 100 km, and 18 within 300 km. At the other extreme, Subotica is about 250 km north of Uzice, the furthest listed city in Serbia.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Cacak | 40 km east | 117,000 | expansion and contraction loosening joints |
| Valjevo | 46 km north | 61,000 | expansion and contraction loosening joints |
| Kraljevo | 69 km east | 83,000 | brittle insulation and hard starting |
| Kragujevac | 87 km east | 147,000 | brittle insulation and hard starting |
| Novi Pazar | 96 km south-east | 86,000 | expansion and contraction loosening joints |
| Trstenik | 97 km east | 49,000 | brittle insulation and hard starting |
In a smaller city like Uzice, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Uzice
The clock in Uzice follows UTC+1, moving to UTC+2 while daylight saving applies.
Sunlight at 43.9° N (Uzice): about 15 h 28 min of daylight in June, about 8 h 54 min in December, and a noon sun that reaches 70° in June and 23° in December. The sun climbs high in summer, so shade and ventilation around outdoor units matter. Uzice has a continental climate, the same as the country as a whole, and 18 other listed cities share it.
Typical uses of capacitors in Uzice
Capacitors are most often specified in Uzice for:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Uzice
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Serbia uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Uzice
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Uzice lies in the northern hemisphere, where cooling demand usually peaks from June to August. Schedule inspections of capacitors for April or May, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Uzice
Shipments for Uzice normally clear customs at one of the main entry points of Serbia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Serbia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Uzice: common questions
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Uzice?
Serbia supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Uzice?
To order capacitors for Uzice, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Uzice can I order for?
Enquiries are welcome from every part of Uzice. Send the delivery address with your enquiry.
Which cities near Uzice can the same order serve?
The listed cities closest to Uzice are Cacak (40 km east), Valjevo (46 km north) and Kraljevo (69 km east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Uzice?
Uzice keeps UTC+1, moving to UTC+2 while daylight saving applies. At 43.9° N there are about 15 h 28 min of daylight in June and about 8 h 54 min in December.
More Klima products for Uzice
- Klima Contactors in Uzice
- Klima Terminal Crimps in Uzice
- Klima Transformer for HVAC in Uzice
- Klima PVC Tapes in Uzice
- Klima Flux Powder (100 g & 250 g) in Uzice
- Klima Delay on Make Timer in Uzice