Capacitors for Nitra
Nitra is a smaller city in Slovakia. The climate is continental. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Demand for capacitors comes mostly from offices, shops and malls as well as factories and workshops. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Nitra for a quotation.
- Country
- Slovakia
- Population
- 86,000
- Climate
- Continental
- Coordinates
- 48.3° N, 18.1° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Bratislava
- 75 km east
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Nitra · Klima Capacitors overview
Capacitors and the climate in Nitra
In Nitra, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
Cities around Nitra that need capacitors
Nitra ranks 3rd of the 17 listed cities in Slovakia and holds about 5.9% of the people living in them, about 20% of the size of Bratislava, the largest. The capital, Bratislava, is about 75 km away, to the west of Nitra. It is about the same size as Miaoli in Taiwan, which has 86,000.
Nearest to Nitra: Komarno (27 km south-east), Nove Zamky (36 km south) and Trnava (38 km west). Nine other listed cities lie within 100 km, and 16 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Komarno | 27 km south-east | 32,000 | brittle insulation and hard starting |
| Nove Zamky | 36 km south | 37,000 | brittle insulation and hard starting |
| Trnava | 38 km west | 63,000 | brittle insulation and hard starting |
| Trencin | 65 km north | 58,000 | expansion and contraction loosening joints |
| Prievidza | 66 km north-east | 44,000 | brittle insulation and hard starting |
| Bratislava | 75 km west | 424,000 | expansion and contraction loosening joints |
In a smaller city like Nitra, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Nitra
The clock in Nitra follows UTC+1, moving to UTC+2 while daylight saving applies.
Nitra lies at 48.3° N, 18.1° E. Daylight lasts about 16 h 06 min at the June solstice and about 8 h 19 min in December, with a noon sun 65° and 18° high; the sun climbs high in summer, so shade and ventilation around outdoor units matter. The climate in Nitra is continental, in line with the rest of Slovakia; 16 other listed cities share it.
Typical uses of capacitors in Nitra
Typical work in Nitra that needs capacitors:
- Packaged rooftop units and ducted systems
- Fan coil unit and blower motors
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Nitra
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- For continental conditions in Nitra, allow for wide seasonal temperature swings.
Care and maintenance in Nitra
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Nitra is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service capacitors in April or May, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- A swollen, bulging or leaking case
Getting capacitors to Nitra
Shipments for Nitra normally clear customs at one of the main entry points of Slovakia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Slovakia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Nitra
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Nitra?
With a 230 V, 50 Hz supply, Slovakia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Nitra?
To order capacitors for Nitra, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Nitra can I order for?
Enquiries are welcome from every part of Nitra. Send the delivery address with your enquiry.
Which cities near Nitra can the same order serve?
The listed cities closest to Nitra are Komarno (27 km south-east), Nove Zamky (36 km south) and Trnava (38 km west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Nitra?
Nitra keeps UTC+1, moving to UTC+2 while daylight saving applies. At 48.3° N there are about 16 h 06 min of daylight in June and about 8 h 19 min in December.
More Klima products for Nitra
- Klima Contactors in Nitra
- Klima Terminal Crimps in Nitra
- Klima Transformer for HVAC in Nitra
- Klima Cables (3 & 4 Core) in Nitra
- Klima Filter Driers in Nitra
- Klima Map Gas (Brazing & Welding) in Nitra