Klima Capacitors supplied to Sejong
Sejong is a mid-sized city in South Korea. The climate is continental. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
The main users of capacitors in Sejong are offices, shops and malls as well as factories and workshops. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Sejong are welcome.
- Country
- South Korea
- Population
- 395,000
- Climate
- Continental
- Coordinates
- 36.6° N, 127.3° E
- Time zone
- UTC+9 all year
- From Seoul
- 112 km south
- Supply
- 220 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Sejong · Klima Capacitors overview
Conditions in Sejong that affect capacitors
In Sejong, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
Where capacitors go from Sejong
Among the 37 listed cities in South Korea, Sejong comes 20th by population, with about 1.1% of the listed urban population, roughly 3.8% of the size of the largest city, Seoul. Sejong lies about 112 km south of Seoul, the capital. For scale, Bologna in Italy has a similar population (395,000).
Nearest to Sejong: Cheongju-si (18 km east), Cheonan (27 km north-west) and Daejeon (28 km south). 13 other listed cities lie within 100 km, and 35 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Cheongju-si | 18 km east | 852,000 | brittle insulation and hard starting |
| Cheonan | 27 km north-west | 659,000 | brittle insulation and hard starting |
| Daejeon | 28 km south | 1.4 million | expansion and contraction loosening joints |
| Pyeongtaek | 48 km north | 365,000 | expansion and contraction loosening joints |
| Osan | 65 km north | 239,000 | brittle insulation and hard starting |
| Chungju | 71 km north-east | 209,000 | expansion and contraction loosening joints |
A mid-sized city like Sejong may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
The sun and the clock in Sejong
The clock in Sejong follows UTC+9 all year.
Sunlight at 36.6° N (Sejong): about 14 h 40 min of daylight in June, about 9 h 39 min in December, and a noon sun that reaches 77° in June and 30° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Sejong has a continental climate, the same as the country as a whole, and 19 other listed cities share it.
Jobs in Sejong that call for capacitors
Capacitors are most often specified in Sejong for:
- Condensing units for walk-in cold rooms
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Sejong
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: South Korea uses 220 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Sejong
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check capacitors in Sejong. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Faults to watch for
- A swollen, bulging or leaking case
Getting capacitors to Sejong
To order capacitors for Sejong, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for South Korea are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Sejong
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Sejong?
South Korea uses 220 V at 60 Hz, so check that capacitors are rated for that voltage and for 60 Hz operation before you order.
How are capacitors delivered to Sejong?
Shipments for Sejong normally clear customs at one of the main entry points of South Korea and finish the journey by road; send your delivery address with the enquiry.
Which parts of Sejong can I order for?
Enquiries are welcome from every part of Sejong. Send the delivery address with your enquiry.
Which cities near Sejong can the same order serve?
The listed cities closest to Sejong are Cheongju-si (18 km east), Cheonan (27 km north-west) and Daejeon (28 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Sejong?
Sejong keeps UTC+9 all year. At 36.6° N there are about 14 h 40 min of daylight in June and about 9 h 39 min in December.
More Klima products for Sejong
- Klima Contactors in Sejong
- Klima Terminal Crimps in Sejong
- Klima Transformer for HVAC in Sejong
- Klima Drier Core 48-KL in Sejong
- Klima Flux Powder (100 g & 250 g) in Sejong
- Klima Thermostat Guards in Sejong