Klima Capacitors in Guro, Seoul
Guro is an industrial area in Seoul, South Korea. Typical customers are maintenance contractors, plant operators and workshops, and what they want is exact-match replacements, fast turnaround and trade quantities.
The main users of capacitors in Guro, Seoul are factories and workshops as well as cold stores and food distribution. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Guro, Seoul for a quotation.
- Area type
- Industrial area
- City
- Seoul
- Country
- South Korea
- Climate
- Continental
- Supply
- 220 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Guro, Seoul · Klima Capacitors overview
What Guro, Seoul demands of capacitors
In Guro, Seoul, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Low temperatures make plastics brittle and slow some electrical parts; let cold capacitors warm up before fitting where you can, and never force a terminal.
The market in Guro, Seoul
Alongside Seongdong, Yeongdeungpo, Gangnam and Jongno, Guro is one of 11 named areas in Seoul, a city of about 10.3 million people, the national capital.
Industrial users in Guro switch heavy motor loads many times a day, so contactors and capacitors need generous duty ratings and tight terminals, not just a matching nameplate.
Where Guro fits in Seoul
Guro is one of 11 areas listed for Seoul, and one of 3 classed as industrial areas. Other industrial areas in Seoul include Geumcheon and Seongdong. The rest of the areas listed for Seoul are Jongno, Mapo, Songpa, Yeongdeungpo and Yongsan.
Where capacitors are used in Guro, Seoul
Typical work in Guro, Seoul that needs capacitors:
- Chiller and air-cooled condenser fans
- Commercial display fridges and freezers
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Guro, Seoul
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Ask for the datasheet and the documents your project needs; in South Korea that usually means KC certification.
Care and maintenance in Guro, Seoul
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Because Guro, Seoul is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service capacitors in April or May, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Supply and delivery to Guro, Seoul
Deliveries for Guro are arranged to Seoul; give a street address or a collection point in your enquiry.
National rules, standards and voltage for South Korea are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Guro, Seoul: common questions
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Guro, Seoul?
The mains supply in South Korea is 220 V, 60 Hz. Some equipment is built for other markets, so confirm the voltage and frequency printed on the nameplate and match the capacitor to it.
How are capacitors delivered to Guro, Seoul?
Send the delivery address in Guro, or a collection point in Seoul, together with the model and quantity you need.
What do buyers in Guro usually need?
Guro is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for Guro, Seoul
- Klima Contactors in Guro, Seoul
- Klima Terminal Crimps in Guro, Seoul
- Klima Transformer for HVAC in Guro, Seoul
- Klima Condensate Pump in Guro, Seoul
- Klima Pressure Switches (High & Low) in Guro, Seoul
- Klima PVC Tapes in Guro, Seoul