Wonju: Klima Capacitors
With about 333,000 people, Wonju is a mid-sized city in South Korea. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
The main users of capacitors in Wonju are offices, shops and malls as well as factories and workshops. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Wonju are welcome.
- Country
- South Korea
- Population
- 333,000
- Climate
- Continental
- Coordinates
- 37.4° N, 127.9° E
- Time zone
- UTC+9 all year
- From Seoul
- 89 km east
- Supply
- 220 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Wonju · Klima Capacitors overview
What Wonju demands of capacitors
In Wonju, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
In winter the cold stiffens cable and plastic insulation, so handle capacitors carefully, avoid sharp bends in cold PVC and check connections after the first hard frost.
Where capacitors go from Wonju
By population Wonju is 23rd of the 37 cities listed for South Korea, with roughly 0.9% of their combined population, roughly 3.2% of the size of the largest city, Seoul. Wonju lies about 89 km east of Seoul, the capital. It is about the same size as Tepic in Mexico, which has 333,000.
In the directory the nearest cities are Chungju (42 km south), Icheon-si (45 km west) and Chuncheon (61 km north). 12 other listed cities lie within 100 km, and 34 within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Chungju | 42 km south | 209,000 | brittle insulation and hard starting |
| Icheon-si | 45 km west | 196,000 | expansion and contraction loosening joints |
| Chuncheon | 61 km north | 285,000 | expansion and contraction loosening joints |
| Osan | 81 km west | 239,000 | brittle insulation and hard starting |
| Suwon | 83 km west | 1.2 million | expansion and contraction loosening joints |
| Pyeongtaek | 86 km south-west | 365,000 | brittle insulation and hard starting |
A mid-sized city like Wonju may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Time zone, sun and daylight in Wonju
Wonju keeps UTC+9 all year.
At 37.4° N, Wonju has about 14 h 44 min of daylight at the June solstice and about 9 h 35 min at the December solstice. The noon sun stands 76° above the horizon in June and 29° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Wonju is continental, in line with the rest of South Korea; 19 other listed cities share it.
Jobs in Wonju that call for capacitors
Capacitors are most often specified in Wonju for:
- Split and window air conditioners
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Wonju
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- Confirm the supply first: South Korea uses 220 V at 60 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Wonju
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Wonju lies in the northern hemisphere, where cooling demand usually peaks from June to August. Schedule inspections of capacitors for April or May, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A swollen, bulging or leaking case
Supply and delivery to Wonju
To order capacitors for Wonju, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for South Korea are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Wonju: common questions
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Wonju?
South Korea uses 220 V at 60 Hz, so check that capacitors are rated for that voltage and for 60 Hz operation before you order.
How are capacitors delivered to Wonju?
Shipments for Wonju normally clear customs at one of the main entry points of South Korea and finish the journey by road; send your delivery address with the enquiry.
Which parts of Wonju can I order for?
Enquiries are welcome from every part of Wonju. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Wonju?
Wonju keeps UTC+9 all year. At 37.4° N there are about 14 h 44 min of daylight in June and about 9 h 35 min in December.
Which cities near Wonju can the same order serve?
The listed cities closest to Wonju are Chungju (42 km south), Icheon-si (45 km west) and Chuncheon (61 km north). Combine them into one order and give each delivery address.
More Klima products for Wonju
- Klima Contactors in Wonju
- Klima Terminal Crimps in Wonju
- Klima Transformer for HVAC in Wonju
- Klima Pressure Switches (High & Low) in Wonju
- Klima Copper Coils & Tubes in Wonju
- Klima Drier Core 48-KL in Wonju