Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Beigang · Klima Capacitors overview
What Beigang demands of capacitors
In Beigang, cooling demand peaks through a long, humid summer. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Capacitors in Beigang and the cities near it
Among the 27 listed cities in Taiwan, Beigang comes 23rd by population, with about 0.2% of the listed urban population, roughly 0.4% of the size of the largest city, Taipei. The capital, Taipei, is about 206 km away, to the north-east of Beigang. For scale, Ziniare in Burkina Faso has a similar population (33,000).
Nearest to Beigang: Chiayi City (18 km south-east), Budai (26 km south-west) and Douliu (29 km north-east). 13 other listed cities lie within 100 km, and 26 within 300 km. At the other extreme, Jincheng is about 223 km north-west of Beigang, the furthest listed city in Taiwan.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Chiayi City | 18 km south-east | 263,000 | moisture on terminals and corrosion |
| Budai | 26 km south-west | 19,000 | terminals loosening and parts running hot |
| Douliu | 29 km north-east | 108,000 | terminals loosening and parts running hot |
| Xinying | 29 km south | 75,000 | terminals loosening and parts running hot |
| Erlin | 37 km north | 44,000 | moisture on terminals and corrosion |
| Pitou | 40 km north-east | 29,000 | moisture on terminals and corrosion |
In a smaller city like Beigang, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Daylight and sun angle in Beigang
Beigang keeps UTC+8 all year.
Sunlight at 23.6° N (Beigang): about 13 h 35 min of daylight in June, about 10 h 41 min in December, and a noon sun that reaches 90° in June and 43° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Beigang has a humid subtropical climate, the same as the country as a whole, and 19 other listed cities share it.
Jobs in Beigang that call for capacitors
Typical work in Beigang that needs capacitors:
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
- Chiller and air-cooled condenser fans
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Beigang
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Ask for the datasheet and the documents your project needs; in Taiwan that usually means BSMI requirements for regulated products.
Care and maintenance in Beigang
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Beigang lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of capacitors for April or May, ahead of that peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- A swollen, bulging or leaking case
Getting capacitors to Beigang
Shipments for Beigang normally clear customs at one of the main entry points of Taiwan and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Taiwan are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Beigang
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Beigang?
Taiwan supplies 110 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
How are capacitors delivered to Beigang?
To order capacitors for Beigang, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Beigang can I order for?
Enquiries are welcome from every part of Beigang. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Beigang?
Beigang keeps UTC+8 all year. At 23.6° N there are about 13 h 35 min of daylight in June and about 10 h 41 min in December.
Which cities near Beigang can the same order serve?
The listed cities closest to Beigang are Chiayi City (18 km south-east), Budai (26 km south-west) and Douliu (29 km north-east). Combine them into one order and give each delivery address.
More Klima products for Beigang
- Klima Contactors in Beigang
- Klima Terminal Crimps in Beigang
- Klima Transformer for HVAC in Beigang
- Klima Condensate Pump in Beigang
- Klima Cables (3 & 4 Core) in Beigang
- Klima Pressure Switches (High & Low) in Beigang