Tataouine: Klima Capacitors
Found in Tunisia, Tataouine is a smaller city with a hot and arid climate. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Demand for capacitors comes mostly from offices, shops and malls as well as factories and workshops. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Tataouine are welcome.
- Country
- Tunisia
- Population
- 67,000
- Climate
- Hot and arid
- Coordinates
- 32.9° N, 10.5° E
- Time zone
- UTC+1 all year
- From Tunis
- 433 km south
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Tataouine · Klima Capacitors overview
Capacitors and the climate in Tataouine
In Tataouine, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Dust and sand work their way into outdoor control boxes; closed covers, intact gaskets and regular cleaning keep capacitors cooler and connections reliable.
Capacitors in Tataouine and the cities near it
Among the 22 listed cities in Tunisia, Tataouine comes 20th by population, with about 2.3% of the listed urban population, about 9.7% of the size of Tunis, the largest. From Tunis, the capital, Tataouine is roughly 433 km to the south. It is about the same size as Seinajoki in Finland, which has 67,000.
Nearest to Tataouine: Medenine (48 km north), Ben Gardane (75 km east) and Zarzis (89 km north-east). Three other listed cities lie within 100 km, and 10 within 300 km. The farthest listed city in Tunisia is Bizerte, about 486 km north of Tataouine.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Medenine | 48 km north | 71,000 | terminals loosening and parts running hot |
| Ben Gardane | 75 km east | 87,000 | terminals loosening and parts running hot |
| Zarzis | 89 km north-east | 79,000 | terminals loosening and parts running hot |
| Gabes | 111 km north | 110,000 | dust on contacts and blocked cooling |
| Houmt Souk | 112 km north | 89,000 | dust on contacts and blocked cooling |
| Sfax | 203 km north | 281,000 | terminals loosening and parts running hot |
In a smaller city like Tataouine, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Tataouine
Local time in Tataouine is UTC+1 all year.
Tataouine lies at 32.9° N, 10.5° E. Daylight lasts about 14 h 20 min at the June solstice and about 9 h 59 min in December, with a noon sun 81° and 34° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Unlike the Mediterranean country as a whole, Tataouine is hot and arid; 5 other listed cities share it.
Where capacitors are used in Tataouine
Capacitors are most often specified in Tataouine for:
- Fan coil unit and blower motors
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Tataouine
- Choose a temperature class suited to where the unit sits. Rooftop and sun-baked installations need parts rated for higher ambient temperatures.
- For hot and arid conditions in Tataouine, favour higher temperature ratings and some margin on every rated value.
Care and maintenance in Tataouine
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Tataouine lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of capacitors for March or April, ahead of that peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Supply and delivery to Tataouine
To order capacitors for Tataouine, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Tunisia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Tataouine
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Tataouine?
With a 230 V, 50 Hz supply, Tunisia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Tataouine?
Shipments for Tataouine normally clear customs at one of the main entry points of Tunisia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Tataouine can I order for?
Enquiries are welcome from every part of Tataouine. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Tataouine?
Tataouine keeps UTC+1 all year. At 32.9° N there are about 14 h 20 min of daylight in June and about 9 h 59 min in December.
Which cities near Tataouine can the same order serve?
The listed cities closest to Tataouine are Medenine (48 km north), Ben Gardane (75 km east) and Zarzis (89 km north-east). Combine them into one order and give each delivery address.
More Klima products for Tataouine
- Klima Contactors in Tataouine
- Klima Terminal Crimps in Tataouine
- Klima Transformer for HVAC in Tataouine
- Klima Filter Driers in Tataouine
- Klima Thermostats in Tataouine
- Klima Temperature Controllers in Tataouine