Klima capacitors for Belfast
With about 348,000 people, Belfast is a mid-sized city in the United Kingdom (Northern Ireland). Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
Capacitors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Belfast.
- Country
- United Kingdom
- Population
- 348,000
- Climate
- Temperate
- Region
- Northern Ireland
- Coordinates
- 54.6° N, 5.9° W
- Time zone
- UTC+0, moving to UTC+1 while daylight saving applies
- From London
- 518 km north-west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Belfast · Klima Capacitors overview
What Belfast demands of capacitors
In Belfast, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.
Capacitors in Belfast and the cities near it
By population Belfast is 13th of the 41 cities listed for the United Kingdom, with roughly 1.6% of their combined population, roughly 3.9% of the size of the largest city, London. The capital, London, is about 518 km away, to the south-east of Belfast. It is about the same size as Camaguey in Cuba, which has 348,000.
In the directory the nearest cities are Glasgow (176 km north-east), Edinburgh (229 km north-east) and Preston (229 km south-east). No other listed city lies within 100 km, and 14 lie within 300 km. The farthest listed city in the United Kingdom is Brighton, about 572 km south-east of Belfast.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Glasgow | 176 km north-east | 626,000 | moisture on terminals and corrosion |
| Edinburgh | 229 km north-east | 515,000 | moisture on terminals and corrosion |
| Preston | 229 km south-east | 313,000 | moisture on terminals and corrosion |
| Birkenhead | 233 km south-east | 325,000 | moisture on terminals and corrosion |
| Liverpool | 233 km south-east | 497,000 | moisture on terminals and corrosion |
| St Helens | 244 km south-east | 183,000 | moisture on terminals and corrosion |
A mid-sized city like Belfast may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Time zone, sun and daylight in Belfast
Local time in Belfast is UTC+0, moving to UTC+1 while daylight saving applies.
Sunlight at 54.6° N (Belfast): about 17 h 17 min of daylight in June, about 7 h 15 min in December, and a noon sun that reaches 59° in June and 12° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Belfast is temperate, in line with the rest of the United Kingdom; 40 other listed cities share it.
Typical uses of capacitors in Belfast
In Belfast, these are the jobs that most often call for capacitors:
- Chiller and air-cooled condenser fans
- Fan coil unit and blower motors
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Belfast
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- For temperate conditions in Belfast, allow for wide seasonal temperature swings.
Care and maintenance in Belfast
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Belfast lies in the northern hemisphere, where cooling demand usually peaks in July and August. Schedule inspections of capacitors for May or June, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Getting capacitors to Belfast
Shipments for Belfast normally clear customs at one of the main entry points of the United Kingdom and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for the United Kingdom are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Belfast
How long does a capacitor last?
Life depends on temperature, voltage and duty. In hot climates capacitors age faster, so replacing a suspect capacitor at the first sign of weak starting is far cheaper than replacing a compressor.
What voltage should capacitors be rated for in Belfast?
The mains supply in the United Kingdom is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Belfast?
To order capacitors for Belfast, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Belfast can I order for?
Enquiries are welcome from every part of Belfast. Send the delivery address with your enquiry.
Which cities near Belfast can the same order serve?
The listed cities closest to Belfast are Glasgow (176 km north-east), Edinburgh (229 km north-east) and Preston (229 km south-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Belfast?
Belfast keeps UTC+0, moving to UTC+1 while daylight saving applies. At 54.6° N there are about 17 h 17 min of daylight in June and about 7 h 15 min in December.
More Klima products for Belfast
- Klima Contactors in Belfast
- Klima Terminal Crimps in Belfast
- Klima Transformer for HVAC in Belfast
- Klima Thermostats in Belfast
- Klima Pressure Switches (High & Low) in Belfast
- Klima Cables (3 & 4 Core) in Belfast