Klima Capacitors in El Tigre
With about 222,000 people, El Tigre is a smaller city in Venezuela. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in El Tigre are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from El Tigre for a quotation.
- Country
- Venezuela
- Population
- 222,000
- Climate
- Hot and humid tropical
- Coordinates
- 8.9° N, 64.3° W
- Time zone
- UTC-4 all year
- From Caracas
- 338 km south-east
- Supply
- 120 V, 60 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for El Tigre · Klima Capacitors overview
Capacitors and the climate in El Tigre
In El Tigre, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Capacitors in El Tigre and the cities near it
El Tigre ranks 25th of the 29 listed cities in Venezuela and holds about 1.4% of the people living in them, about 7.4% of the size of Caracas, the largest. El Tigre lies about 338 km south-east of Caracas, the capital. It is about the same size as Haeju in North Korea, which has 222,000.
Nearest to El Tigre: Ciudad Bolivar (115 km south-east), Barcelona (147 km north) and Maturin (151 km north-east). No other listed city lies within 100 km, and seven lie within 300 km. The farthest listed city in Venezuela is San Cristobal, about 887 km west of El Tigre.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Ciudad Bolivar | 115 km south-east | 413,000 | moisture on terminals and corrosion |
| Barcelona | 147 km north | 815,000 | terminals loosening and parts running hot |
| Maturin | 151 km north-east | 647,000 | moisture on terminals and corrosion |
| Puerto La Cruz | 153 km north | 370,000 | terminals loosening and parts running hot |
| Cumana | 175 km north | 406,000 | moisture on terminals and corrosion |
| Ciudad Guayana | 187 km east | 978,000 | moisture on terminals and corrosion |
In a smaller city like El Tigre, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in El Tigre
El Tigre keeps UTC-4 all year.
Sunlight at 8.9° N (El Tigre): about 12 h 38 min of daylight in June, about 11 h 36 min in December, and a noon sun that reaches 75° in June and 58° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in El Tigre is hot and humid tropical, in line with the rest of Venezuela; 28 other listed cities share it.
Typical uses of capacitors in El Tigre
Capacitors are most often specified in El Tigre for:
- Packaged rooftop units and ducted systems
- Heat pump outdoor units
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in El Tigre
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Ask for the datasheet and the documents your project needs; in Venezuela that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).
Care and maintenance in El Tigre
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
With little seasonal change in temperature, air conditioning in El Tigre works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to El Tigre
To order capacitors for El Tigre, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Venezuela are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in El Tigre: common questions
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in El Tigre?
Venezuela supplies 120 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of capacitors against the nameplate.
How are capacitors delivered to El Tigre?
Shipments for El Tigre normally clear customs at one of the main entry points of Venezuela and finish the journey by road; send your delivery address with the enquiry.
Which parts of El Tigre can I order for?
Enquiries are welcome from every part of El Tigre. Send the delivery address with your enquiry.
What local time and daylight should I plan for in El Tigre?
El Tigre keeps UTC-4 all year. At 8.9° N there are about 12 h 38 min of daylight in June and about 11 h 36 min in December.
Which cities near El Tigre can the same order serve?
The listed cities closest to El Tigre are Ciudad Bolivar (115 km south-east), Barcelona (147 km north) and Maturin (151 km north-east). Combine them into one order and give each delivery address.
More Klima products for El Tigre
- Klima Contactors in El Tigre
- Klima Terminal Crimps in El Tigre
- Klima Transformer for HVAC in El Tigre
- Klima PVC Tapes in El Tigre
- Klima Map Gas (Brazing & Welding) in El Tigre
- Klima Condensate Pump in El Tigre