Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Phu My · Klima Capacitors overview
Conditions in Phu My that affect capacitors
In Phu My, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Cities around Phu My that need capacitors
By population Phu My is 24th of the 47 cities listed for Vietnam, with roughly 0.7% of their combined population, about 2.1% of the size of Ho Chi Minh City, the largest. The capital, Hanoi, is about 1,163 km away, to the north of Phu My. It is about the same size as Katowice in Poland, which has 287,000.
The closest are Thanh Pho Ba Ria (19 km south-east), Vung Tau (32 km south) and Xuan Loc (38 km north-east). Eight other listed cities lie within 100 km, and 20 within 300 km. The farthest listed city in Vietnam is Thai Nguyen, about 1,226 km north of Phu My.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Thanh Pho Ba Ria | 19 km south-east | 235,000 | terminals loosening and parts running hot |
| Vung Tau | 32 km south | 465,000 | moisture on terminals and corrosion |
| Xuan Loc | 38 km north-east | 253,000 | moisture on terminals and corrosion |
| Bien Hoa | 44 km north-west | 1.3 million | moisture on terminals and corrosion |
| Ho Chi Minh City | 52 km north-west | 14 million | moisture on terminals and corrosion |
| Tan An | 72 km west | 215,000 | moisture on terminals and corrosion |
A mid-sized city like Phu My may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Daylight and sun angle in Phu My
The clock in Phu My follows UTC+7 all year.
At 10.6° N, Phu My has about 12 h 45 min of daylight at the June solstice and about 11 h 30 min at the December solstice. The noon sun stands 77° above the horizon in June and 56° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Phu My is hot and humid tropical, in line with the rest of Vietnam; 46 other listed cities share it.
Where capacitors are used in Phu My
Capacitors are most often specified in Phu My for:
- Fan coil unit and blower motors
- Split and window air conditioners
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Phu My
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Vietnam uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Phu My
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
A tropical climate keeps cooling demand steady through the year in Phu My, so there is no quiet season. Schedule checks of capacitors around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A swollen, bulging or leaking case
Ordering capacitors for Phu My
To order capacitors for Phu My, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Vietnam are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Phu My: common questions
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Phu My?
With a 230 V, 50 Hz supply, Vietnam follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Phu My?
Shipments for Phu My normally clear customs at one of the main entry points of Vietnam and finish the journey by road; send your delivery address with the enquiry.
Which parts of Phu My can I order for?
Enquiries are welcome from every part of Phu My. Send the delivery address with your enquiry.
Which cities near Phu My can the same order serve?
The listed cities closest to Phu My are Thanh Pho Ba Ria (19 km south-east), Vung Tau (32 km south) and Xuan Loc (38 km north-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Phu My?
Phu My keeps UTC+7 all year. At 10.6° N there are about 12 h 45 min of daylight in June and about 11 h 30 min in December.
More Klima products for Phu My
- Klima Contactors in Phu My
- Klima Terminal Crimps in Phu My
- Klima Transformer for HVAC in Phu My
- Klima Filter Driers in Phu My
- Klima Flux Powder (100 g & 250 g) in Phu My
- Klima Map Gas (Brazing & Welding) in Phu My