Found in Wallis and Futuna, Mata-Utu is a smaller city with a hot and humid tropical climate. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Demand for capacitors comes mostly from offices, shops and malls as well as factories and workshops. The Klima range has 116 models; the table below is a selection, so send an enquiry with the model code and your delivery address in Mata-Utu.

Country
Wallis and Futuna
Population
1,200
Climate
Hot and humid tropical
Coordinates
13.3° S, 176.2° W
Time zone
UTC+12 all year
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Mata-Utu · Klima Capacitors overview

Conditions in Mata-Utu that affect capacitors

In Mata-Utu, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.

Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

The market in Mata-Utu

Mata-Utu is the only city listed for Wallis and Futuna, with about 1,200 people. Enquiries from anywhere in the country can use this page.

In a smaller city like Mata-Utu, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

Time zone, sun and daylight in Mata-Utu

Mata-Utu keeps UTC+12 all year.

Sunlight at 13.3° S (Mata-Utu): about 11 h 21 min of daylight in June, about 12 h 55 min in December, and a noon sun that reaches 53° in June and 80° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Jobs in Mata-Utu that call for capacitors

Capacitors are most often specified in Mata-Utu for:

  • Split and window air conditioners
  • Fan coil unit and blower motors
  • Ventilation and exhaust fan motors

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Selecting capacitors in Mata-Utu

  • Never go below the original voltage rating. A higher rated voltage is acceptable; a lower one fails early.
  • Confirm the supply first: Wallis and Futuna uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.

Care and maintenance in Mata-Utu

  • Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.

With little seasonal change in temperature, air conditioning in Mata-Utu works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • A humming compressor that fails to start, or a fan that has to be spun by hand

Supply and delivery to Mata-Utu

To order capacitors for Mata-Utu, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Wallis and Futuna are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about capacitors in Mata-Utu

What is the difference between a run capacitor and a start capacitor?

A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.

What voltage should capacitors be rated for in Mata-Utu?

Wallis and Futuna supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are capacitors delivered to Mata-Utu?

Shipments for Mata-Utu normally clear customs at one of the main entry points of Wallis and Futuna and finish the journey by road; send your delivery address with the enquiry.

Which parts of Mata-Utu can I order for?

Enquiries are welcome from every part of Mata-Utu. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Mata-Utu?

Mata-Utu keeps UTC+12 all year. At 13.3° S there are about 11 h 21 min of daylight in June and about 12 h 55 min in December.

More Klima products for Mata-Utu