Klima Industries

Buying copper coils and tubes in Artik

With about 18,000 people, Artik is a smaller city in Armenia. Summers are warm to hot and winters are cold, with a wide swing between the seasons.

Demand for copper coils and tubes comes mostly from offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range includes 6 models, each with a specification table; send an enquiry from Artik for a quotation.

Country
Armenia
Population
18,000
Climate
Continental
Coordinates
40.6° N, 44.0° E
Time zone
UTC+4 all year
From Yerevan
67 km north-west
Supply
230 V, 50 Hz

Klima Copper Coils & Tubes models

All Klima products for Artik · Klima Copper Coils & Tubes overview

Conditions in Artik that affect copper coils and tubes

In Artik, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near copper coils and tubes for oil traces after the first hot and the first cold spells.

In cold weather, shelter the joint from wind, pre-warm the pipe and keep copper coils and tubes at a workable temperature so flux stays smooth and the cylinder keeps its pressure.

Copper coils and tubes in Artik and the cities near it

Artik ranks 11th of the 14 listed cities in Armenia and holds about 1.1% of the people living in them, about 1.6% of the size of Yerevan, the largest. Artik lies about 67 km north-west of Yerevan, the capital.

The closest are Gyumri (22 km north-west), Vanadzor (49 km north-east) and Armavir (52 km south). Eight other listed cities lie within 100 km, and 13 within 300 km. The farthest listed city in Armenia is Kapan, about 260 km south-east of Artik.

CityDistancePeopleWhat wears copper coils and tubes first
Gyumri22 km north-west115,000joint fatigue from temperature swings
Vanadzor49 km north-east78,000low ambient operation and frozen drains
Armavir52 km south30,000low ambient operation and frozen drains
Charentsavan62 km south-east22,000joint fatigue from temperature swings
Hrazdan67 km east50,000low ambient operation and frozen drains
Yerevan67 km south-east1.1 millionjoint fatigue from temperature swings

In a smaller city like Artik, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.

Time zone, sun and daylight in Artik

The clock in Artik follows UTC+4 all year.

Artik lies at 40.6° N, 44.0° E. Daylight lasts about 15 h 05 min at the June solstice and about 9 h 16 min in December, with a noon sun 73° and 26° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. Artik has a continental climate, the same as the country as a whole, and 13 other listed cities share it.

Typical uses of copper coils and tubes in Artik

Copper coils and tubes are most often specified in Artik for:

  • Heat pump refrigerant lines
  • Split-system liquid and suction lines
  • VRF and multi-split branch piping

Klima copper coils and tubes models

ModelSize (in)Outside diameter (mm)Wall thickness (mm)
Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall1/4 in6.350.8
Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall3/8 in9.520.8
Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall1/2 in12.70.8
Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall5/8 in15.881.0

See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.

How to pick copper coils and tubes for work in Artik

  • Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
  • Ask for the datasheet and the documents your project needs; in Armenia that usually means EAC conformity under EAEU technical regulations.

Keeping copper coils and tubes reliable in Artik

  • Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.

In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check copper coils and tubes in Artik. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.

Faults to watch for

  • A system that loses charge slowly

Ordering copper coils and tubes for Artik

Shipments for Artik normally clear customs at one of the main entry points of Armenia and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Armenia are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about copper coils and tubes in Artik

What wall thickness do I need for R410A?

R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.

How does the climate in Artik affect copper coils and tubes?

Wide temperature swings move rigid pipework; leave bends and clips that let the line flex, and check copper coils and tubes connections for slow leaks each season.

How are copper coils and tubes delivered to Artik?

To order copper coils and tubes for Artik, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Artik can I order for?

Enquiries are welcome from every part of Artik. Send the delivery address with your enquiry.

Which cities near Artik can the same order serve?

The listed cities closest to Artik are Gyumri (22 km north-west), Vanadzor (49 km north-east) and Armavir (52 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Artik?

Artik keeps UTC+4 all year. At 40.6° N there are about 15 h 05 min of daylight in June and about 9 h 16 min in December.