Klima Copper Coils & Tubes in Darwin
With about 140,000 people, Darwin is a smaller city in Australia (Northern Territory). Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for copper coils and tubes comes mostly from offices, shops and malls as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Darwin.
- Country
- Australia
- Population
- 140,000
- Climate
- Hot and humid tropical
- Region
- Northern Territory
- Coordinates
- 12.5° S, 130.8° E
- Time zone
- UTC+9:30 all year
- From Canberra
- 3,134 km north-west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Darwin · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Darwin
In Darwin, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Rooftop copper can already be hot to the touch before you light the torch; shade the work, keep copper coils and tubes cool and heat evenly to avoid overheating the joint.
Where copper coils and tubes go from Darwin
Darwin ranks 18th of the 28 listed cities in Australia and holds about 0.6% of the people living in them, about 2.5% of the size of Sydney, the largest. The capital, Canberra, is about 3,134 km away, to the south-east of Darwin. For scale, Amersfoort in the Netherlands has a similar population (140,000).
Nearest to Darwin: Cairns (1,679 km east), Townsville (1,866 km south-east) and Mackay (2,174 km south-east). No other listed city lies within 300 km. At the other extreme, Hobart is about 3,736 km south of Darwin, the furthest listed city in Australia.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Cairns | 1,679 km east | 153,000 | moisture entering the circuit and corrosion |
| Townsville | 1,866 km south-east | 201,000 | moisture entering the circuit and corrosion |
| Mackay | 2,174 km south-east | 84,000 | moisture entering the circuit and corrosion |
| Rockhampton | 2,404 km south-east | 81,000 | moisture entering the circuit and corrosion |
| Adelaide | 2,618 km south | 1.5 million | joint fatigue from temperature swings |
| Perth | 2,653 km south-west | 2.4 million | joint fatigue from temperature swings |
In a smaller city like Darwin, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Time zone, sun and daylight in Darwin
Local time in Darwin is UTC+9:30 all year. That puts it 0.5 hours behind Canberra, so allow for the difference when you book a delivery slot.
Sunlight at 12.5° S (Darwin): about 11 h 23 min of daylight in June, about 12 h 51 min in December, and a noon sun that reaches 54° in June and 79° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Darwin has a hot and humid tropical climate, which differs from the humid subtropical climate that describes Australia overall; 3 other listed cities share it.
Typical uses of copper coils and tubes in Darwin
In Darwin, these are the jobs that most often call for copper coils and tubes:
- VRF and multi-split branch piping
- Display cabinets and ice machines
- Heat pump refrigerant lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Darwin
- Match outside diameter to the service connections on the indoor and outdoor units, and do not mix imperial and metric sizes without adaptors.
- For hot and humid tropical conditions in Darwin, favour sealed, corrosion-resistant construction.
Care and maintenance in Darwin
- Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.
A tropical climate keeps cooling demand steady through the year in Darwin, so there is no quiet season. Schedule checks of copper coils and tubes around the main rainy-season changes and keep spares on hand. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- Oil stains or frost at joints
Supply and delivery to Darwin
To order copper coils and tubes for Darwin, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Australia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Darwin: common questions
What is the difference between a pancake coil and straight tube?
A pancake coil is soft-annealed tube wound flat in a level spiral for easy bending on site. Straight lengths are usually supplied in hard temper for rigid, fixed pipework.
How does the climate in Darwin affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
How are copper coils and tubes delivered to Darwin?
Shipments for Darwin normally clear customs at one of the main entry points of Australia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Darwin can I order for?
Enquiries are welcome from every part of Darwin. Send the delivery address with your enquiry.
Which cities near Darwin can the same order serve?
The listed cities closest to Darwin are Cairns (1,679 km east), Townsville (1,866 km south-east) and Mackay (2,174 km south-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Darwin?
Darwin keeps UTC+9:30 all year. At 12.5° S there are about 11 h 23 min of daylight in June and about 12 h 51 min in December.
More Klima products for Darwin
- Klima Filter Driers in Darwin
- Klima Flux Powder (100 g & 250 g) in Darwin
- Klima Map Gas (Brazing & Welding) in Darwin
- Klima Capacitors in Darwin
- Klima Cables (3 & 4 Core) in Darwin
- Klima Contactors in Darwin