Buying copper coils and tubes in Maceio
With about 1 million people, Maceio is a major city in Brazil. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Copper coils and tubes are bought here mainly for offices, shops and malls as well as factories and workshops. Klima Industries lists 6 models in this range with full specifications below, and enquiries from Maceio are welcome.
- Country
- Brazil
- Population
- 1 million
- Climate
- Hot and humid tropical
- Coordinates
- 9.7° S, 35.7° W
- Time zone
- UTC-3 all year
- From Brasilia
- 1,486 km north-east
- Supply
- 127/220 V, 60 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Maceio · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Maceio
In Maceio, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Rooftop copper can already be hot to the touch before you light the torch; shade the work, keep copper coils and tubes cool and heat evenly to avoid overheating the joint.
Where copper coils and tubes go from Maceio
Among the 60 listed cities in Brazil, Maceio comes 13th by population, with about 1.6% of the listed urban population, roughly 8.3% of the size of the largest city, Sao Paulo. Maceio lies about 1,486 km north-east of Brasilia, the capital. It is about the same size as Rangpur in Bangladesh, which has 1 million.
In the directory the nearest cities are Caruaru (156 km north), Jaboatao dos Guararapes (190 km north-east) and Aracaju (201 km south-west). No other listed city lies within 100 km, and six lie within 300 km.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Caruaru | 156 km north | 402,000 | high head pressure and hot joints |
| Jaboatao dos Guararapes | 190 km north-east | 644,000 | high head pressure and hot joints |
| Aracaju | 201 km south-west | 665,000 | high head pressure and hot joints |
| Recife | 202 km north-east | 1.7 million | high head pressure and hot joints |
| Campina Grande | 271 km north | 349,000 | high head pressure and hot joints |
| Joao Pessoa | 299 km north | 818,000 | high head pressure and hot joints |
In a major city like Maceio, common tube sizes and driers are easy to find; less common sizes or special fittings are worth ordering ahead of the job.
Time zone, sun and daylight in Maceio
Maceio keeps UTC-3 all year.
At 9.7° S, Maceio has about 11 h 34 min of daylight at the June solstice and about 12 h 41 min at the December solstice. The noon sun stands 57° above the horizon in June and 76° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Unlike the humid subtropical country as a whole, Maceio is hot and humid tropical; 28 other listed cities share it.
Jobs in Maceio that call for copper coils and tubes
Typical work in Maceio that needs copper coils and tubes:
- VRF and multi-split branch piping
- Condensing unit to evaporator lines in cold rooms
- Heat pump refrigerant lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Maceio
- Pair liquid and suction lines with insulation of the correct bore and thickness.
- Ask for the datasheet and the documents your project needs; in Brazil that usually means INMETRO certification for regulated products.
Care and maintenance in Maceio
- Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.
With little seasonal change in temperature, air conditioning in Maceio works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- Oil stains or frost at joints
Getting copper coils and tubes to Maceio
Shipments for Maceio normally clear customs at one of the main entry points of Brazil and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Brazil are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Copper coils and tubes in Maceio: common questions
What wall thickness do I need for R410A?
R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.
How does the climate in Maceio affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
How are copper coils and tubes delivered to Maceio?
To order copper coils and tubes for Maceio, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Maceio can I order for?
Enquiries are welcome from every part of Maceio. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Maceio?
Maceio keeps UTC-3 all year. At 9.7° S there are about 11 h 34 min of daylight in June and about 12 h 41 min in December.
Which cities near Maceio can the same order serve?
The listed cities closest to Maceio are Caruaru (156 km north), Jaboatao dos Guararapes (190 km north-east) and Aracaju (201 km south-west). Combine them into one order and give each delivery address.
More Klima products for Maceio
- Klima Filter Driers in Maceio
- Klima Flux Powder (100 g & 250 g) in Maceio
- Klima Map Gas (Brazing & Welding) in Maceio
- Klima Thermostat Guards in Maceio
- Klima Pressure Switches (High & Low) in Maceio
- Klima Thermostats in Maceio