Klima Copper Coils & Tubes supplied to Pursat
Pursat is a smaller city in Cambodia. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Copper coils and tubes are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Pursat.
- Country
- Cambodia
- Population
- 52,000
- Climate
- Hot and humid tropical
- Coordinates
- 12.5° N, 103.9° E
- Time zone
- UTC+7 all year
- From Phnom Penh
- 153 km north-west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Pursat · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Pursat
In Pursat, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Where copper coils and tubes go from Pursat
Pursat ranks 9th of the 24 listed cities in Cambodia and holds about 1.5% of the people living in them, about 3.3% of the size of Phnom Penh, the largest. The capital, Phnom Penh, is about 153 km away, to the south-east of Pursat. It is about the same size as Nametil in Mozambique, which has 52,000.
In the directory the nearest cities are Siem Reap (92 km north), Battambang (100 km north-west) and Phumi Veal Tonsay (118 km south-east). Two other listed cities lie within 100 km, and 23 within 300 km. The farthest listed city in Cambodia is Bavet, about 292 km south-east of Pursat.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Siem Reap | 92 km north | 139,000 | high head pressure and hot joints |
| Battambang | 100 km north-west | 119,000 | high head pressure and hot joints |
| Phumi Veal Tonsay | 118 km south-east | 25,000 | moisture entering the circuit and corrosion |
| Koh Kong | 145 km south-west | 33,000 | moisture entering the circuit and corrosion |
| Smach Mean Chey | 146 km south-west | 29,000 | high head pressure and hot joints |
| Phnom Penh | 153 km south-east | 1.6 million | high head pressure and hot joints |
In a smaller city like Pursat, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Daylight and sun angle in Pursat
Pursat keeps UTC+7 all year.
Sunlight at 12.5° N (Pursat): about 12 h 52 min of daylight in June, about 11 h 23 min in December, and a noon sun that reaches 79° in June and 54° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Pursat is hot and humid tropical, in line with the rest of Cambodia; 23 other listed cities share it.
Typical uses of copper coils and tubes in Pursat
In Pursat, these are the jobs that most often call for copper coils and tubes:
- VRF and multi-split branch piping
- Heat pump refrigerant lines
- Replacement coils and repair sections
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Pursat
- Pair liquid and suction lines with insulation of the correct bore and thickness.
- Ask for the datasheet and the documents your project needs; in Cambodia that usually means ISC (Institute of Standards of Cambodia) requirements.
Keeping copper coils and tubes reliable in Pursat
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
With little seasonal change in temperature, air conditioning in Pursat works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- Oil stains or frost at joints
Getting copper coils and tubes to Pursat
To order copper coils and tubes for Pursat, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Cambodia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Pursat: common questions
What wall thickness do I need for R410A?
R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.
How does the climate in Pursat affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
How are copper coils and tubes delivered to Pursat?
Shipments for Pursat normally clear customs at one of the main entry points of Cambodia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Pursat can I order for?
Enquiries are welcome from every part of Pursat. Send the delivery address with your enquiry.
Which cities near Pursat can the same order serve?
The listed cities closest to Pursat are Siem Reap (92 km north), Battambang (100 km north-west) and Phumi Veal Tonsay (118 km south-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Pursat?
Pursat keeps UTC+7 all year. At 12.5° N there are about 12 h 52 min of daylight in June and about 11 h 23 min in December.
More Klima products for Pursat
- Klima Filter Driers in Pursat
- Klima Flux Powder (100 g & 250 g) in Pursat
- Klima Map Gas (Brazing & Welding) in Pursat
- Klima Terminal Crimps in Pursat
- Klima Cables (3 & 4 Core) in Pursat
- Klima Temperature Controllers in Pursat