Klima Copper Coils & Tubes supplied to Mit Ghamr
Mit Ghamr is a smaller city in Egypt. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Copper coils and tubes are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 6 models, each with a specification table; send an enquiry from Mit Ghamr for a quotation.
- Country
- Egypt
- Population
- 154,000
- Climate
- Hot and arid
- Coordinates
- 30.7° N, 31.3° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Cairo
- 73 km north
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Mit Ghamr · Klima Copper Coils & Tubes overview
Conditions in Mit Ghamr that affect copper coils and tubes
In Mit Ghamr, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Wind and dust blow the flame away from the joint; use a wind shield, clean the joint thoroughly and keep dust out of flux and gas fittings.
Where copper coils and tubes go from Mit Ghamr
Mit Ghamr ranks 37th of the 48 listed cities in Egypt and holds about 0.5% of the people living in them, roughly 1.6% of the size of the largest city, Cairo. Mit Ghamr lies about 73 km north of Cairo, the capital. It is about the same size as Enschede in the Netherlands, which has 154,000.
In the directory the nearest cities are Tanta (26 km west), Zagazig (27 km south-east) and Banha (29 km south). 22 other listed cities lie within 100 km, and 34 within 300 km. At the other extreme, Aswan is about 754 km south of Mit Ghamr, the furthest listed city in Egypt.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Tanta | 26 km west | 577,000 | dirty condensers raising pressure |
| Zagazig | 27 km south-east | 430,000 | high head pressure and hot joints |
| Banha | 29 km south | 182,000 | dirty condensers raising pressure |
| Al Mahallah al Kubra | 30 km north | 593,000 | high head pressure and hot joints |
| Shibin al Kawm | 30 km south-west | 268,000 | dirty condensers raising pressure |
| Al Mansurah | 38 km north | 622,000 | dirty condensers raising pressure |
In a smaller city like Mit Ghamr, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Daylight and sun angle in Mit Ghamr
Mit Ghamr keeps UTC+2, moving to UTC+3 while daylight saving applies.
At 30.7° N, Mit Ghamr has about 14 h 08 min of daylight at the June solstice and about 10 h 09 min at the December solstice. The noon sun stands 83° above the horizon in June and 36° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Mit Ghamr is hot and arid, in line with the rest of Egypt; 47 other listed cities share it.
Where copper coils and tubes are used in Mit Ghamr
In Mit Ghamr, these are the jobs that most often call for copper coils and tubes:
- VRF and multi-split branch piping
- Marine and offshore refrigeration
- Chiller and package unit refrigerant circuits
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Mit Ghamr
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- Ask for the datasheet and the documents your project needs; in Egypt that usually means EOS (Egyptian Organization for Standardization) conformity.
Keeping copper coils and tubes reliable in Mit Ghamr
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check copper coils and tubes in Mit Ghamr. Replace driers and re-braze suspect joints while the system can be stopped without complaints.
Signs of trouble
- Restricted flow caused by kinks or oxide flakes
Supply and delivery to Mit Ghamr
Shipments for Mit Ghamr normally clear customs at one of the main entry points of Egypt and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Egypt are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Mit Ghamr: common questions
What wall thickness do I need for R410A?
R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.
How does the climate in Mit Ghamr affect copper coils and tubes?
High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
How are copper coils and tubes delivered to Mit Ghamr?
To order copper coils and tubes for Mit Ghamr, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Mit Ghamr can I order for?
Enquiries are welcome from every part of Mit Ghamr. Send the delivery address with your enquiry.
Which cities near Mit Ghamr can the same order serve?
The listed cities closest to Mit Ghamr are Tanta (26 km west), Zagazig (27 km south-east) and Banha (29 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Mit Ghamr?
Mit Ghamr keeps UTC+2, moving to UTC+3 while daylight saving applies. At 30.7° N there are about 14 h 08 min of daylight in June and about 10 h 09 min in December.
More Klima products for Mit Ghamr
- Klima Filter Driers in Mit Ghamr
- Klima Flux Powder (100 g & 250 g) in Mit Ghamr
- Klima Map Gas (Brazing & Welding) in Mit Ghamr
- Klima Cables (3 & 4 Core) in Mit Ghamr
- Klima Thermometers for HVAC in Mit Ghamr
- Klima Capacitors in Mit Ghamr