Copper coils and tubes for Makokou
Makokou is a smaller city in Gabon. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of copper coils and tubes in Makokou are offices, shops and malls as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Makokou.
- Country
- Gabon
- Population
- 25,000
- Climate
- Hot and humid tropical
- Coordinates
- 0.6° N, 12.9° E
- Time zone
- UTC+1 all year
- From Libreville
- 380 km east
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Makokou · Klima Copper Coils & Tubes overview
What Makokou demands of copper coils and tubes
In Makokou, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Rooftop copper can already be hot to the touch before you light the torch; shade the work, keep copper coils and tubes cool and heat evenly to avoid overheating the joint.
Where copper coils and tubes go from Makokou
By population Makokou is 14th of the 14 cities listed for Gabon, with roughly 1.5% of their combined population, roughly 2.9% of the size of the largest city, Libreville. From Libreville, the capital, Makokou is roughly 380 km to the east. For scale, Ebebiyin in Equatorial Guinea has a similar population (25,000).
Nearest to Makokou: Oyem (183 km north-west), Koulamoutou (195 km south) and Bitam (226 km north-west). No other listed city lies within 100 km, and six lie within 300 km. At the other extreme, Port-Gentil is about 476 km west of Makokou, the furthest listed city in Gabon.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Oyem | 183 km north-west | 73,000 | high head pressure and hot joints |
| Koulamoutou | 195 km south | 31,000 | moisture entering the circuit and corrosion |
| Bitam | 226 km north-west | 34,000 | moisture entering the circuit and corrosion |
| Moanda | 241 km south | 71,000 | moisture entering the circuit and corrosion |
| Oyam | 257 km west | 30,000 | high head pressure and hot joints |
| Franceville | 258 km south | 133,000 | moisture entering the circuit and corrosion |
In a smaller city like Makokou, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
The sun and the clock in Makokou
The clock in Makokou follows UTC+1 all year.
At 0.6° N, Makokou has about 12 h 09 min of daylight at the June solstice and about 12 h 05 min at the December solstice. The noon sun stands 67° above the horizon in June and 66° in December, and the summer sun is high, so outdoor units in unshaded spots take strong direct heat. Makokou has a hot and humid tropical climate, the same as the country as a whole, and 13 other listed cities share it.
Where copper coils and tubes are used in Makokou
In Makokou, these are the jobs that most often call for copper coils and tubes:
- Split-system liquid and suction lines
- VRF and multi-split branch piping
- Heat pump refrigerant lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Makokou
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- For hot and humid tropical conditions in Makokou, favour sealed, corrosion-resistant construction.
Keeping copper coils and tubes reliable in Makokou
- Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.
A tropical climate keeps cooling demand steady through the year in Makokou, so there is no quiet season. Schedule checks of copper coils and tubes around the main rainy-season changes and keep spares on hand. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Faults to watch for
- A system that loses charge slowly
Ordering copper coils and tubes for Makokou
To order copper coils and tubes for Makokou, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Gabon are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Makokou: common questions
Which copper tube is used for air conditioners?
Seamless refrigeration-grade (ACR) copper tube, cleaned and capped, is used for refrigerant lines. Common air conditioner sizes include 1/4, 3/8, 1/2, 5/8 and 3/4 inch outside diameters.
How does the climate in Makokou affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
How are copper coils and tubes delivered to Makokou?
Shipments for Makokou normally clear customs at one of the main entry points of Gabon and finish the journey by road; send your delivery address with the enquiry.
Which parts of Makokou can I order for?
Enquiries are welcome from every part of Makokou. Send the delivery address with your enquiry.
Which cities near Makokou can the same order serve?
The listed cities closest to Makokou are Oyem (183 km north-west), Koulamoutou (195 km south) and Bitam (226 km north-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Makokou?
Makokou keeps UTC+1 all year. At 0.6° N there are about 12 h 09 min of daylight in June and about 12 h 05 min in December.
More Klima products for Makokou
- Klima Filter Driers in Makokou
- Klima Flux Powder (100 g & 250 g) in Makokou
- Klima Map Gas (Brazing & Welding) in Makokou
- Klima Thermostat Guards in Makokou
- Klima PVC Tapes in Makokou
- Klima Thermostats in Makokou