Hohoe: Klima Copper Coils & Tubes
Hohoe is a smaller city in Ghana. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Copper coils and tubes are bought here mainly for offices, shops and malls, homes and apartments as well as hospitals and clinics. The range below has 6 models; send an enquiry with the model code and your delivery address in Hohoe.
- Country
- Ghana
- Population
- 92,000
- Climate
- Hot and humid tropical
- Coordinates
- 7.2° N, 0.5° E
- Time zone
- UTC+0 all year
- From Accra
- 192 km north-east
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Hohoe · Klima Copper Coils & Tubes overview
Conditions in Hohoe that affect copper coils and tubes
In Hohoe, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
Rooftop copper can already be hot to the touch before you light the torch; shade the work, keep copper coils and tubes cool and heat evenly to avoid overheating the joint.
Copper coils and tubes in Hohoe and the cities near it
Hohoe ranks 14th of the 30 listed cities in Ghana and holds about 1.2% of the people living in them, roughly 3.6% of the size of the largest city, Kumasi. Hohoe lies about 192 km north-east of Accra, the capital. It is about the same size as Nasinu in Fiji, which has 92,000.
Nearest to Hohoe: Ho (61 km south), Aflao (139 km south-east) and Koforidua (143 km south-west). One other listed city lies within 100 km, and 20 within 300 km. The farthest listed city in Ghana is Jirapa, about 513 km north-west of Hohoe.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Ho | 61 km south | 131,000 | high head pressure and hot joints |
| Aflao | 139 km south-east | 67,000 | high head pressure and hot joints |
| Koforidua | 143 km south-west | 151,000 | high head pressure and hot joints |
| Suhum | 160 km south-west | 51,000 | high head pressure and hot joints |
| Atsiaman | 184 km south-west | 203,000 | high head pressure and hot joints |
| Accra | 192 km south-west | 2 million | moisture entering the circuit and corrosion |
In a smaller city like Hohoe, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Time zone, sun and daylight in Hohoe
The clock in Hohoe follows UTC+0 all year.
Hohoe lies at 7.2° N, 0.5° E. Daylight lasts about 12 h 32 min at the June solstice and about 11 h 42 min in December, with a noon sun 74° and 59° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Hohoe is hot and humid tropical, in line with the rest of Ghana; 29 other listed cities share it.
Where copper coils and tubes are used in Hohoe
In Hohoe, these are the jobs that most often call for copper coils and tubes:
- Condensing unit to evaporator lines in cold rooms
- Heat pump refrigerant lines
- Split-system liquid and suction lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Hohoe
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- For hot and humid tropical conditions in Hohoe, favour sealed, corrosion-resistant construction.
Keeping copper coils and tubes reliable in Hohoe
- Keep pipe ends capped until the moment of brazing so moisture and dirt stay out.
With little seasonal change in temperature, air conditioning in Hohoe works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Signs of trouble
- A system that loses charge slowly
Getting copper coils and tubes to Hohoe
Shipments for Hohoe normally clear customs at one of the main entry points of Ghana and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Ghana are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about copper coils and tubes in Hohoe
How much pipe do I need?
Measure the route between the units, add 10 to 15 % for bends and trimming, and choose a coil or straight lengths that match the route to waste as little as possible.
How does the climate in Hohoe affect copper coils and tubes?
Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
How are copper coils and tubes delivered to Hohoe?
To order copper coils and tubes for Hohoe, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Hohoe can I order for?
Enquiries are welcome from every part of Hohoe. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Hohoe?
Hohoe keeps UTC+0 all year. At 7.2° N there are about 12 h 32 min of daylight in June and about 11 h 42 min in December.
Which cities near Hohoe can the same order serve?
The listed cities closest to Hohoe are Ho (61 km south), Aflao (139 km south-east) and Koforidua (143 km south-west). Combine them into one order and give each delivery address.
More Klima products for Hohoe
- Klima Filter Driers in Hohoe
- Klima Flux Powder (100 g & 250 g) in Hohoe
- Klima Map Gas (Brazing & Welding) in Hohoe
- Klima Contactors in Hohoe
- Klima Temperature Controllers in Hohoe
- Klima Terminal Crimps in Hohoe