Copper coils and tubes for Bet Shemesh
Bet Shemesh is a smaller city in Israel. The climate is Mediterranean. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Demand for copper coils and tubes comes mostly from offices, shops and malls, homes and apartments as well as hospitals and clinics. The range below has 6 models; send an enquiry with the model code and your delivery address in Bet Shemesh.
- Country
- Israel
- Population
- 125,000
- Climate
- Mediterranean
- Coordinates
- 31.7° N, 35.0° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Jerusalem
- 22 km west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Bet Shemesh · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Bet Shemesh
In Bet Shemesh, cooling demand peaks from late spring to early autumn. High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
Changeable weather means wind one hour and still air the next; carry a heat shield and a wind screen, and re-check the flame at each joint.
Where copper coils and tubes go from Bet Shemesh
Among the 20 listed cities in Israel, Bet Shemesh comes 14th by population, with about 2.8% of the listed urban population, about 13% of the size of Jerusalem, the largest. The capital, Jerusalem, is about 22 km away, to the east of Bet Shemesh. It is about the same size as Az Zulfi in Saudi Arabia, which has 125,000.
In the directory the nearest cities are Jerusalem (22 km east), West Jerusalem (22 km east) and Kiryat Gat (25 km south-west). 16 other listed cities lie within 100 km, and 19 within 300 km. At the other extreme, Nahariyya is about 142 km north of Bet Shemesh, the furthest listed city in Israel.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Jerusalem | 22 km east | 972,000 | high head pressure and hot joints |
| West Jerusalem | 22 km east | 400,000 | joint fatigue from temperature swings |
| Kiryat Gat | 25 km south-west | 62,000 | joint fatigue from temperature swings |
| Rehovot | 25 km north-west | 149,000 | joint fatigue from temperature swings |
| Ashdod | 33 km west | 227,000 | joint fatigue from temperature swings |
| Rishon LeTsiyyon | 33 km north-west | 259,000 | high head pressure and hot joints |
In a smaller city like Bet Shemesh, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Daylight and sun angle in Bet Shemesh
The clock in Bet Shemesh follows UTC+2, moving to UTC+3 while daylight saving applies.
Bet Shemesh lies at 31.7° N, 35.0° E. Daylight lasts about 14 h 13 min at the June solstice and about 10 h 04 min in December, with a noon sun 82° and 35° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Bet Shemesh is Mediterranean, in line with the rest of Israel; 19 other listed cities share it.
Typical uses of copper coils and tubes in Bet Shemesh
Typical work in Bet Shemesh that needs copper coils and tubes:
- Heat pump refrigerant lines
- Condensing unit to evaporator lines in cold rooms
- Split-system liquid and suction lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Bet Shemesh
- Pair liquid and suction lines with insulation of the correct bore and thickness.
- Ask for the datasheet and the documents your project needs; in Israel that usually means SII (Standards Institution of Israel) requirements.
Keeping copper coils and tubes reliable in Bet Shemesh
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
Bet Shemesh lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of copper coils and tubes for April or May, ahead of that peak. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Faults to watch for
- Restricted flow caused by kinks or oxide flakes
Ordering copper coils and tubes for Bet Shemesh
Shipments for Bet Shemesh normally clear customs at one of the main entry points of Israel and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Israel are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Copper coils and tubes in Bet Shemesh: common questions
How do I join copper tube?
By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.
How does the climate in Bet Shemesh affect copper coils and tubes?
In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.
How are copper coils and tubes delivered to Bet Shemesh?
To order copper coils and tubes for Bet Shemesh, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Bet Shemesh can I order for?
Enquiries are welcome from every part of Bet Shemesh. Send the delivery address with your enquiry.
Which cities near Bet Shemesh can the same order serve?
The listed cities closest to Bet Shemesh are Jerusalem (22 km east), West Jerusalem (22 km east) and Kiryat Gat (25 km south-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Bet Shemesh?
Bet Shemesh keeps UTC+2, moving to UTC+3 while daylight saving applies. At 31.7° N there are about 14 h 13 min of daylight in June and about 10 h 04 min in December.
More Klima products for Bet Shemesh
- Klima Filter Driers in Bet Shemesh
- Klima Flux Powder (100 g & 250 g) in Bet Shemesh
- Klima Map Gas (Brazing & Welding) in Bet Shemesh
- Klima Pressure Switches (High & Low) in Bet Shemesh
- Klima Delay on Make Timer in Bet Shemesh
- Klima Contactors in Bet Shemesh