Divo: Klima Copper Coils & Tubes
With about 137,000 people, Divo is a smaller city in Ivory Coast. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of copper coils and tubes in Divo are offices, shops and malls as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Divo.
- Country
- Ivory Coast
- Population
- 137,000
- Climate
- Hot and humid tropical
- Coordinates
- 5.8° N, 5.4° W
- Time zone
- UTC+0 all year
- From Yamoussoukro
- 110 km south
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Divo · Klima Copper Coils & Tubes overview
What Divo demands of copper coils and tubes
In Divo, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Copper coils and tubes in Divo and the cities near it
By population Divo is 12th of the 28 cities listed for Ivory Coast, with roughly 1.2% of their combined population, about 2.2% of the size of Abidjan, the largest. From Yamoussoukro, the capital, Divo is roughly 110 km to the south. For scale, Apeldoorn in the Netherlands has a similar population (137,000).
In the directory the nearest cities are Gagnoa (73 km north-west), Sinfra (107 km north-west) and Yamoussoukro (110 km north). One other listed city lies within 100 km, and 23 within 300 km. At the other extreme, Ferkessedougou is about 418 km north of Divo, the furthest listed city in Ivory Coast.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Gagnoa | 73 km north-west | 277,000 | high head pressure and hot joints |
| Sinfra | 107 km north-west | 245,000 | high head pressure and hot joints |
| Yamoussoukro | 110 km north | 276,000 | moisture entering the circuit and corrosion |
| Dimbokro | 115 km north-east | 70,000 | high head pressure and hot joints |
| Dabou | 123 km south-east | 138,000 | moisture entering the circuit and corrosion |
| Agboville | 127 km east | 82,000 | moisture entering the circuit and corrosion |
In a smaller city like Divo, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
Daylight and sun angle in Divo
Local time in Divo is UTC+0 all year.
Sunlight at 5.8° N (Divo): about 12 h 28 min of daylight in June, about 11 h 47 min in December, and a noon sun that reaches 72° in June and 61° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat. Divo has a hot and humid tropical climate, the same as the country as a whole, and 27 other listed cities share it.
Typical uses of copper coils and tubes in Divo
In Divo, these are the jobs that most often call for copper coils and tubes:
- Split-system liquid and suction lines
- Condensing unit to evaporator lines in cold rooms
- Heat pump refrigerant lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Divo
- Match outside diameter to the service connections on the indoor and outdoor units, and do not mix imperial and metric sizes without adaptors.
- For hot and humid tropical conditions in Divo, favour sealed, corrosion-resistant construction.
Keeping copper coils and tubes reliable in Divo
- Bend with a proper bender; kinked tube restricts flow and fatigues at the crease.
With little seasonal change in temperature, air conditioning in Divo works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- Oil stains or frost at joints
Getting copper coils and tubes to Divo
To order copper coils and tubes for Divo, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Ivory Coast are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about copper coils and tubes in Divo
How do I join copper tube?
By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.
How does the climate in Divo affect copper coils and tubes?
Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
How are copper coils and tubes delivered to Divo?
Shipments for Divo normally clear customs at one of the main entry points of Ivory Coast and finish the journey by road; send your delivery address with the enquiry.
Which parts of Divo can I order for?
Enquiries are welcome from every part of Divo. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Divo?
Divo keeps UTC+0 all year. At 5.8° N there are about 12 h 28 min of daylight in June and about 11 h 47 min in December.
Which cities near Divo can the same order serve?
The listed cities closest to Divo are Gagnoa (73 km north-west), Sinfra (107 km north-west) and Yamoussoukro (110 km north). Combine them into one order and give each delivery address.
More Klima products for Divo
- Klima Filter Driers in Divo
- Klima Flux Powder (100 g & 250 g) in Divo
- Klima Map Gas (Brazing & Welding) in Divo
- Klima Pressure Switches (High & Low) in Divo
- Klima Thermostat Guards in Divo
- Klima Terminal Crimps in Divo