Klima Copper Coils & Tubes supplied to Man
With about 242,000 people, Man is a smaller city in Ivory Coast. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of copper coils and tubes in Man are offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 6 models in this range with full specifications below, and enquiries from Man are welcome.
- Country
- Ivory Coast
- Population
- 242,000
- Climate
- Hot and humid tropical
- Coordinates
- 7.4° N, 7.6° W
- Time zone
- UTC+0 all year
- From Yamoussoukro
- 260 km west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Man · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Man
In Man, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Where copper coils and tubes go from Man
By population Man is 9th of the 28 cities listed for Ivory Coast, with roughly 2.1% of their combined population, roughly 3.8% of the size of the largest city, Abidjan. From Yamoussoukro, the capital, Man is roughly 260 km to the west. For scale, Bahawalnagar in Pakistan has a similar population (242,000).
In the directory the nearest cities are Danane (68 km west), Duekoue (78 km south) and Seguela (115 km north-east). Two other listed cities lie within 100 km, and 15 within 300 km. The farthest listed city in Ivory Coast is Bondoukou, about 528 km east of Man.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Danane | 68 km west | 79,000 | moisture entering the circuit and corrosion |
| Duekoue | 78 km south | 117,000 | moisture entering the circuit and corrosion |
| Seguela | 115 km north-east | 104,000 | high head pressure and hot joints |
| Vavoua | 119 km east | 87,000 | high head pressure and hot joints |
| Daloa | 136 km south-east | 422,000 | high head pressure and hot joints |
| Issia | 148 km south-east | 68,000 | high head pressure and hot joints |
In a smaller city like Man, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
The sun and the clock in Man
Man keeps UTC+0 all year.
Man lies at 7.4° N, 7.6° W. Daylight lasts about 12 h 33 min at the June solstice and about 11 h 41 min in December, with a noon sun 74° and 59° high; the sun climbs high in summer, so shade and ventilation around outdoor units matter. Man has a hot and humid tropical climate, the same as the country as a whole, and 27 other listed cities share it.
Jobs in Man that call for copper coils and tubes
Copper coils and tubes are most often specified in Man for:
- Split-system liquid and suction lines
- VRF and multi-split branch piping
- Condensing unit to evaporator lines in cold rooms
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Man
- Pair liquid and suction lines with insulation of the correct bore and thickness.
- For hot and humid tropical conditions in Man, favour sealed, corrosion-resistant construction.
Keeping copper coils and tubes reliable in Man
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
With little seasonal change in temperature, air conditioning in Man works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- Restricted flow caused by kinks or oxide flakes
Getting copper coils and tubes to Man
Shipments for Man normally clear customs at one of the main entry points of Ivory Coast and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Ivory Coast are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Copper coils and tubes in Man: common questions
How do I join copper tube?
By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.
How does the climate in Man affect copper coils and tubes?
Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
How are copper coils and tubes delivered to Man?
To order copper coils and tubes for Man, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Man can I order for?
Enquiries are welcome from every part of Man. Send the delivery address with your enquiry.
Which cities near Man can the same order serve?
The listed cities closest to Man are Danane (68 km west), Duekoue (78 km south) and Seguela (115 km north-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Man?
Man keeps UTC+0 all year. At 7.4° N there are about 12 h 33 min of daylight in June and about 11 h 41 min in December.
More Klima products for Man
- Klima Filter Driers in Man
- Klima Flux Powder (100 g & 250 g) in Man
- Klima Map Gas (Brazing & Welding) in Man
- Klima Thermostat Guards in Man
- Klima PVC Tapes in Man
- Klima Delay on Make Timer in Man