Copper coils and tubes for Ban Khoan
With about 65,000 people, Ban Khoan is a smaller city in Laos. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of copper coils and tubes in Ban Khoan are offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 6 models in this range with full specifications below, and enquiries from Ban Khoan are welcome.
- Country
- Laos
- Population
- 65,000
- Climate
- Hot and humid tropical
- Coordinates
- 20.4° N, 100.1° E
- Time zone
- UTC+7 all year
- From Vientiane
- 374 km north-west
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Ban Khoan · Klima Copper Coils & Tubes overview
What Ban Khoan demands of copper coils and tubes
In Ban Khoan, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Where copper coils and tubes go from Ban Khoan
Among the 18 listed cities in Laos, Ban Khoan comes 5th by population, with about 4.2% of the listed urban population, roughly 7.8% of the size of the largest city, Vientiane. From Vientiane, the capital, Ban Khoan is roughly 374 km to the north-west. For scale, Urgut Shahri in Uzbekistan has a similar population (65,000).
In the directory the nearest cities are Ban Houakhoua (40 km east), Muang Sing (144 km north-east) and Muang Xay (201 km east). One other listed city lies within 100 km, and five within 300 km. At the other extreme, Sekong is about 896 km south-east of Ban Khoan, the furthest listed city in Laos.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Ban Houakhoua | 40 km east | 16,000 | moisture entering the circuit and corrosion |
| Muang Sing | 144 km north-east | 24,000 | moisture entering the circuit and corrosion |
| Muang Xay | 201 km east | 25,000 | high head pressure and hot joints |
| Luang Prabang | 221 km east | 55,000 | moisture entering the circuit and corrosion |
| Vang Vieng | 293 km south-east | 25,000 | high head pressure and hot joints |
| Muang Phonsavan | 339 km east | 38,000 | moisture entering the circuit and corrosion |
In a smaller city like Ban Khoan, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.
The sun and the clock in Ban Khoan
The clock in Ban Khoan follows UTC+7 all year.
Sunlight at 20.4° N (Ban Khoan): about 13 h 22 min of daylight in June, about 10 h 54 min in December, and a noon sun that reaches 87° in June and 46° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Ban Khoan has a hot and humid tropical climate, the same as the country as a whole, and 17 other listed cities share it.
Where copper coils and tubes are used in Ban Khoan
Copper coils and tubes are most often specified in Ban Khoan for:
- Split-system liquid and suction lines
- VRF and multi-split branch piping
- Heat pump refrigerant lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Ban Khoan
- Choose wall thickness for the refrigerant: R410A and R32 need heavier walls than R22 or R134a.
- For hot and humid tropical conditions in Ban Khoan, favour sealed, corrosion-resistant construction.
Care and maintenance in Ban Khoan
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
With little seasonal change in temperature, air conditioning in Ban Khoan works almost every day. Spread checks of copper coils and tubes through the year instead of waiting for a peak. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Faults to watch for
- Restricted flow caused by kinks or oxide flakes
Getting copper coils and tubes to Ban Khoan
Shipments for Ban Khoan normally clear customs at one of the main entry points of Laos and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Laos are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Ban Khoan: common questions
Can I reuse old copper pipe?
Old pipe can be reused only if it is the right size and wall thickness, clean inside and pressure tested. Contaminated or oil-stained pipe is safer replaced.
How does the climate in Ban Khoan affect copper coils and tubes?
Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
How are copper coils and tubes delivered to Ban Khoan?
To order copper coils and tubes for Ban Khoan, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Ban Khoan can I order for?
Enquiries are welcome from every part of Ban Khoan. Send the delivery address with your enquiry.
Which cities near Ban Khoan can the same order serve?
The listed cities closest to Ban Khoan are Ban Houakhoua (40 km east), Muang Sing (144 km north-east) and Muang Xay (201 km east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Ban Khoan?
Ban Khoan keeps UTC+7 all year. At 20.4° N there are about 13 h 22 min of daylight in June and about 10 h 54 min in December.
More Klima products for Ban Khoan
- Klima Filter Driers in Ban Khoan
- Klima Flux Powder (100 g & 250 g) in Ban Khoan
- Klima Map Gas (Brazing & Welding) in Ban Khoan
- Klima Capacitors in Ban Khoan
- Klima Cables (3 & 4 Core) in Ban Khoan
- Klima Thermometers for HVAC in Ban Khoan