Klima Industries

Gaya: Klima Copper Coils & Tubes

Gaya is a smaller city in Niger. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Copper coils and tubes are bought here mainly for offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range includes 6 models, each with a specification table; send an enquiry from Gaya for a quotation.

Country
Niger
Population
62,000
Climate
Hot and arid
Coordinates
11.9° N, 3.4° E
Time zone
UTC+1 all year
From Niamey
232 km south-east
Supply
230 V, 50 Hz

Klima Copper Coils & Tubes models

All Klima products for Gaya · Klima Copper Coils & Tubes overview

Conditions in Gaya that affect copper coils and tubes

In Gaya, air conditioning and refrigeration run for most of the year. High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.

Wind and dust blow the flame away from the joint; use a wind shield, clean the joint thoroughly and keep dust out of flux and gas fittings.

Cities around Gaya that need copper coils and tubes

By population Gaya is 10th of the 27 cities listed for Niger, with roughly 1.8% of their combined population, roughly 4.6% of the size of the largest city, Niamey. From Niamey, the capital, Gaya is roughly 232 km to the south-east. It is about the same size as Mora in Cameroon, which has 62,000.

The closest are Dosso (132 km north), Dogondoutchi (205 km north) and Niamey (232 km north-west). No other listed city lies within 100 km, and four lie within 300 km.

CityDistancePeopleWhat wears copper coils and tubes first
Dosso132 km north79,000high head pressure and hot joints
Dogondoutchi205 km north50,000dirty condensers raising pressure
Niamey232 km north-west1.3 milliondirty condensers raising pressure
Birni N Konni289 km north-east85,000high head pressure and hot joints
Tillaberi337 km north-west31,000high head pressure and hot joints
Illela346 km north-east30,000dirty condensers raising pressure

In a smaller city like Gaya, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.

Daylight and sun angle in Gaya

The clock in Gaya follows UTC+1 all year.

At 11.9° N, Gaya has about 12 h 49 min of daylight at the June solstice and about 11 h 26 min at the December solstice. The noon sun stands 78° above the horizon in June and 55° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Gaya is hot and arid, in line with the rest of Niger; 26 other listed cities share it.

Jobs in Gaya that call for copper coils and tubes

Copper coils and tubes are most often specified in Gaya for:

  • Split-system liquid and suction lines
  • VRF and multi-split branch piping
  • Heat pump refrigerant lines

Klima copper coils and tubes models

ModelSize (in)Outside diameter (mm)Wall thickness (mm)
Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall1/4 in6.350.8
Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall3/8 in9.520.8
Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall1/2 in12.70.8
Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall5/8 in15.881.0

See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.

How to pick copper coils and tubes for work in Gaya

  • Order enough length for the full run plus waste for bends and brazing off-cuts.
  • Ask for the datasheet and the documents your project needs; in Niger that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Keeping copper coils and tubes reliable in Gaya

  • Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.

Because Gaya is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service copper coils and tubes in March or April, while the load is still light. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.

Faults to watch for

  • A system that loses charge slowly

Ordering copper coils and tubes for Gaya

Shipments for Gaya normally clear customs at one of the main entry points of Niger and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Niger are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about copper coils and tubes in Gaya

What wall thickness do I need for R410A?

R410A runs at a higher pressure than R22, so installers normally use heavier-wall tube. Check the equipment manual and your local refrigeration code for the minimum wall thickness for each pipe size.

How does the climate in Gaya affect copper coils and tubes?

In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.

How are copper coils and tubes delivered to Gaya?

To order copper coils and tubes for Gaya, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Gaya can I order for?

Enquiries are welcome from every part of Gaya. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Gaya?

Gaya keeps UTC+1 all year. At 11.9° N there are about 12 h 49 min of daylight in June and about 11 h 26 min in December.

Which cities near Gaya can the same order serve?

The listed cities closest to Gaya are Dosso (132 km north), Dogondoutchi (205 km north) and Niamey (232 km north-west). Combine them into one order and give each delivery address.

More Klima products for Gaya

Copper coils and tubes in cities near Gaya