Klima Industries

Klima copper coils and tubes for Tanout

Tanout is a smaller city in Niger. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Demand for copper coils and tubes comes mostly from offices, shops and malls as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Tanout.

Country
Niger
Population
28,000
Climate
Hot and arid
Coordinates
15.0° N, 8.9° E
Time zone
UTC+1 all year
From Niamey
748 km east
Supply
230 V, 50 Hz

Klima Copper Coils & Tubes models

All Klima products for Tanout · Klima Copper Coils & Tubes overview

What Tanout demands of copper coils and tubes

In Tanout, air conditioning and refrigeration run for most of the year. High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.

Wind and dust blow the flame away from the joint; use a wind shield, clean the joint thoroughly and keep dust out of flux and gas fittings.

Cities around Tanout that need copper coils and tubes

Tanout ranks 25th of the 27 listed cities in Niger and holds about 0.8% of the people living in them, roughly 2.1% of the size of the largest city, Niamey. Tanout lies about 748 km east of Niamey, the capital. For scale, Bouansa in the Republic of the Congo has a similar population (28,000).

Nearest to Tanout: Zinder (130 km south), Mirriah (143 km south) and Tessaoua (166 km south-west). No other listed city lies within 100 km, and 11 lie within 300 km. The farthest listed city in Niger is Tera, about 882 km west of Tanout.

CityDistancePeopleWhat wears copper coils and tubes first
Zinder130 km south319,000dirty condensers raising pressure
Mirriah143 km south38,000dirty condensers raising pressure
Tessaoua166 km south-west59,000high head pressure and hot joints
Matamey178 km south37,000high head pressure and hot joints
Goure185 km south-east25,000dirty condensers raising pressure
Magaria219 km south35,000dirty condensers raising pressure

In a smaller city like Tanout, tube, driers and brazing supplies may need to come from further away. Order enough for the whole job and keep consumables dry and sealed.

The sun and the clock in Tanout

Local time in Tanout is UTC+1 all year.

Tanout lies at 15.0° N, 8.9° E. Daylight lasts about 13 h 01 min at the June solstice and about 11 h 14 min in December, with a noon sun 82° and 52° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Tanout has a hot and arid climate, the same as the country as a whole, and 26 other listed cities share it.

Where copper coils and tubes are used in Tanout

Copper coils and tubes are most often specified in Tanout for:

  • VRF and multi-split branch piping
  • Heat pump refrigerant lines
  • Split-system liquid and suction lines

Klima copper coils and tubes models

ModelSize (in)Outside diameter (mm)Wall thickness (mm)
Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall1/4 in6.350.8
Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall3/8 in9.520.8
Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall1/2 in12.70.8
Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall5/8 in15.881.0

See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.

Selecting copper coils and tubes in Tanout

  • Pair liquid and suction lines with insulation of the correct bore and thickness.
  • For hot and arid conditions in Tanout, favour higher temperature ratings and some margin on every rated value.

Care and maintenance in Tanout

  • Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.

Tanout lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of copper coils and tubes for March or April, ahead of that peak. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.

Faults to watch for

  • Restricted flow caused by kinks or oxide flakes

Getting copper coils and tubes to Tanout

To order copper coils and tubes for Tanout, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Niger are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Copper coils and tubes in Tanout: common questions

How do I join copper tube?

By brazing with a suitable filler rod and flux where required, or by flare and compression fittings on small sizes. Always purge with nitrogen while brazing and pressure test afterwards.

How does the climate in Tanout affect copper coils and tubes?

In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.

How are copper coils and tubes delivered to Tanout?

Shipments for Tanout normally clear customs at one of the main entry points of Niger and finish the journey by road; send your delivery address with the enquiry.

Which parts of Tanout can I order for?

Enquiries are welcome from every part of Tanout. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Tanout?

Tanout keeps UTC+1 all year. At 15.0° N there are about 13 h 01 min of daylight in June and about 11 h 14 min in December.

Which cities near Tanout can the same order serve?

The listed cities closest to Tanout are Zinder (130 km south), Mirriah (143 km south) and Tessaoua (166 km south-west). Combine them into one order and give each delivery address.

More Klima products for Tanout

Copper coils and tubes in cities near Tanout