Copper coils and tubes supply in Harare
As the capital of Zimbabwe, Harare is a major city with about 1.5 million people. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.
The main users of copper coils and tubes in Harare are offices, shops and malls, homes and apartments as well as hospitals and clinics. The Klima range includes 6 models, each with a specification table; send an enquiry from Harare for a quotation.
- Country
- Zimbabwe
- Population
- 1.5 million
- Climate
- Highland
- Coordinates
- 17.8° S, 31.1° E
- Time zone
- UTC+2 all year
- Supply
- 230 V, 50 Hz
- Status
- National capital
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Harare · Klima Copper Coils & Tubes overview
Copper coils and tubes and the climate in Harare
In Harare, cooling demand is moderate, and refrigeration and process loads stay steady all year. At altitude ambient pressure is lower, so gauge readings sit lower for the same absolute pressure; use a gauge zeroed on site when you set or test copper coils and tubes.
Changeable weather means wind one hour and still air the next; carry a heat shield and a wind screen, and re-check the flame at each joint.
Cities around Harare that need copper coils and tubes
By population Harare is first of the 24 cities listed for Zimbabwe, with roughly 38% of their combined population, about 2.3 times the size of Bulawayo, the next largest. It is about the same size as Monrovia in Liberia, which has 1.5 million.
Nearest to Harare: Chitungwiza (21 km south), Norton (38 km west) and Bindura (65 km north-east). Four other listed cities lie within 100 km, and 16 within 300 km. At the other extreme, Victoria Falls is about 553 km west of Harare, the furthest listed city in Zimbabwe.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Chitungwiza | 21 km south | 371,000 | moisture entering the circuit and corrosion |
| Norton | 38 km west | 87,000 | moisture entering the circuit and corrosion |
| Bindura | 65 km north-east | 50,000 | moisture entering the circuit and corrosion |
| Marondera | 66 km south-east | 66,000 | high head pressure and hot joints |
| Chegutu | 102 km west | 66,000 | moisture entering the circuit and corrosion |
| Chinhoyi | 104 km north-west | 91,000 | high head pressure and hot joints |
In a major city like Harare, common tube sizes and driers are easy to find; less common sizes or special fittings are worth ordering ahead of the job.
Harare has 9 areas listed in this directory, including industrial areas such as Workington, Belvedere and Ardbennie, commercial districts such as Eastlea and residential districts such as Borrowdale and Avondale. Each area has its own supply page, linked below.
Daylight and sun angle in Harare
Local time in Harare is UTC+2 all year.
Harare lies at 17.8° S, 31.1° E. Daylight lasts about 11 h 04 min at the June solstice and about 13 h 12 min in December, with a noon sun 49° and 84° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Harare has a highland climate, the same as the country as a whole, and no other listed city shares it.
Jobs in Harare that call for copper coils and tubes
Typical work in Harare that needs copper coils and tubes:
- VRF and multi-split branch piping
- Heat pump refrigerant lines
- Split-system liquid and suction lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
Selecting copper coils and tubes in Harare
- Order enough length for the full run plus waste for bends and brazing off-cuts.
- For highland conditions in Harare, allow extra rating margin for thin air.
Care and maintenance in Harare
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
Cooling demand at altitude in Harare is lower than in the lowlands but still real, and cold nights add refrigeration and heating work. Plan checks of copper coils and tubes at the change of season. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Signs of trouble
- Oil stains or frost at joints
Getting copper coils and tubes to Harare
To order copper coils and tubes for Harare, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Zimbabwe are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about copper coils and tubes in Harare
Can I reuse old copper pipe?
Old pipe can be reused only if it is the right size and wall thickness, clean inside and pressure tested. Contaminated or oil-stained pipe is safer replaced.
How does the climate in Harare affect copper coils and tubes?
Thin air changes how condensers reject heat and how gauges read, so verify the settings of copper coils and tubes with a calibrated gauge and the maker notes for high altitude.
How are copper coils and tubes delivered to Harare?
Shipments for Harare normally clear customs at one of the main entry points of Zimbabwe and finish the journey by road; send your delivery address with the enquiry.
Which parts of Harare can I order for?
Enquiries are welcome from every part of Harare, including Ardbennie, Avondale, Belvedere, Borrowdale, Eastlea, Graniteside, Msasa and Southerton. Send the delivery address with your enquiry.
Which cities near Harare can the same order serve?
The listed cities closest to Harare are Chitungwiza (21 km south), Norton (38 km west) and Bindura (65 km north-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Harare?
Harare keeps UTC+2 all year. At 17.8° S there are about 11 h 04 min of daylight in June and about 13 h 12 min in December.
More Klima products for Harare
- Klima Filter Driers in Harare
- Klima Flux Powder (100 g & 250 g) in Harare
- Klima Map Gas (Brazing & Welding) in Harare
- Klima Condensate Pump in Harare
- Klima Terminal Crimps in Harare
- Klima Capacitors in Harare