Klima Industries

Kwekwe: Klima Delay on Make Timer

With about 120,000 people, Kwekwe is a smaller city in Zimbabwe. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.

Delay on make timers are bought here mainly for offices, shops and malls, hospitals and clinics as well as homes and apartments. The range below has 4 models; send an enquiry with the model code and your delivery address in Kwekwe.

Country
Zimbabwe
Population
120,000
Climate
Humid subtropical
Coordinates
18.9° S, 29.8° E
Time zone
UTC+2 all year
From Harare
179 km south-west
Supply
230 V, 50 Hz

Klima Delay on Make Timer models

All Klima products for Kwekwe · Klima Delay on Make Timer overview

What Kwekwe demands of delay on make timers

In Kwekwe, cooling demand peaks through a long, humid summer. High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed delay on make timers and keep control boxes closed with their gaskets intact.

In very hot weather a badly placed control keeps the compressor running; mount delay on make timers out of direct sun and away from heat sources.

Where delay on make timers go from Kwekwe

Kwekwe ranks 6th of the 24 listed cities in Zimbabwe and holds about 2.9% of the people living in them, about 7.8% of the size of Harare, the largest. The capital, Harare, is about 179 km away, to the north-east of Kwekwe. It is about the same size as Malindi in Kenya, which has 120,000.

The closest are Gweru (58 km south), Kadoma (67 km north) and Chegutu (95 km north). Three other listed cities lie within 100 km, and 18 within 300 km. The farthest listed city in Zimbabwe is Victoria Falls, about 435 km west of Kwekwe.

CityDistancePeopleWhat wears delay on make timers first
Gweru58 km south158,000condensation inside enclosures
Kadoma67 km north117,000sensor drift and setpoints creeping
Chegutu95 km north66,000sensor drift and setpoints creeping
Gokwe123 km north-west33,000condensation inside enclosures
Norton149 km north-east87,000sensor drift and setpoints creeping
Zvishavane158 km south60,000condensation inside enclosures

In a smaller city like Kwekwe, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Kwekwe

Local time in Kwekwe is UTC+2 all year.

At 18.9° S, Kwekwe has about 10 h 59 min of daylight at the June solstice and about 13 h 16 min at the December solstice. The noon sun stands 48° above the horizon in June and 85° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Unlike the highland country as a whole, Kwekwe is humid subtropical; 22 other listed cities share it.

Typical uses of delay on make timers in Kwekwe

Typical work in Kwekwe that needs delay on make timers:

  • Split and ducted air conditioners
  • Rooftop packaged units
  • Cold rooms and refrigeration condensing units

Klima delay on make timers models

ModelSupply voltage (V)Delay rangeContact rating (A)
Klima Delay on Make Timer, Fixed, 24 V AC/DC24 V AC/DC3 min fixed5
Klima Delay on Make Timer, Fixed, 230 V AC230 V AC3 min fixed5
Klima Delay on Make Timer, Adjustable, 24 V AC/DC24 V AC/DC0.1 to 10 min5
Klima Delay on Make Timer, Adjustable, 230 V AC230 V AC0.1 to 10 min5

See the full Klima Delay on Make Timer range for specifications, standards and a plain-language guide to choosing the right part.

How to pick delay on make timers for work in Kwekwe

  • Set the delay to the compressor maker's recommended off-time; three to five minutes is typical for hermetic compressors.
  • For humid subtropical conditions in Kwekwe, favour sealed, corrosion-resistant construction.

Care and maintenance in Kwekwe

  • Replace the timer if the delay drifts or fails to latch.

Kwekwe lies in the southern hemisphere, where cooling demand usually peaks from December to March. Schedule inspections of delay on make timers for October or November, ahead of that peak. Controls drift over time; verify setpoints and switch points before the demanding months.

Signs of trouble

  • Repeated overload trips or clicking contactors

Supply and delivery to Kwekwe

Shipments for Kwekwe normally clear customs at one of the main entry points of Zimbabwe and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Zimbabwe are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about delay on make timers in Kwekwe

How long should the delay be?

Follow the compressor manufacturer's guidance. Around three to five minutes is common for hermetic air conditioning and refrigeration compressors.

What voltage should delay on make timers be rated for in Kwekwe?

Zimbabwe supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so delay on make timers rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are delay on make timers delivered to Kwekwe?

To order delay on make timers for Kwekwe, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Kwekwe can I order for?

Enquiries are welcome from every part of Kwekwe. Send the delivery address with your enquiry.

Which cities near Kwekwe can the same order serve?

The listed cities closest to Kwekwe are Gweru (58 km south), Kadoma (67 km north) and Chegutu (95 km north). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Kwekwe?

Kwekwe keeps UTC+2 all year. At 18.9° S there are about 10 h 59 min of daylight in June and about 13 h 16 min in December.

More Klima products for Kwekwe

Delay on make timers in cities near Kwekwe