Klima Industries

Klima Pressure Switches (High & Low) in Townsville

With about 201,000 people, Townsville is a smaller city in Australia (Queensland). Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of pressure switches in Townsville are offices, shops and malls, cold stores and food distribution as well as homes and apartments. The range below has 4 models; send an enquiry with the model code and your delivery address in Townsville.

Country
Australia
Population
201,000
Climate
Hot and humid tropical
Region
Queensland
Coordinates
19.3° S, 146.8° E
Time zone
UTC+10 all year
From Canberra
1,796 km north
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Townsville · Klima Pressure Switches (High & Low) overview

Conditions in Townsville that affect pressure switches

In Townsville, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.

Sun-warmed walls make thermostats read high; place pressure switches on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.

Cities around Townsville that need pressure switches

Among the 28 listed cities in Australia, Townsville comes 15th by population, with about 0.9% of the listed urban population, roughly 3.6% of the size of the largest city, Sydney. From Canberra, the capital, Townsville is roughly 1,796 km to the north. For scale, Cajamarca in Peru has a similar population (201,000).

Nearest to Townsville: Cairns (283 km north-west), Mackay (324 km south-east) and Rockhampton (597 km south-east). No other listed city lies within 100 km, and one lies within 300 km.

CityDistancePeopleWhat wears pressure switches first
Cairns283 km north-west153,000sensor drift and setpoints creeping
Mackay324 km south-east84,000sensor drift and setpoints creeping
Rockhampton597 km south-east81,000sensor drift and setpoints creeping
Sunshine Coast1,043 km south-east399,000condensation inside enclosures
Caloundra1,058 km south-east96,000condensation inside enclosures
Toowoomba1,061 km south-east142,000sensor drift and setpoints creeping

In a smaller city like Townsville, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

The sun and the clock in Townsville

The clock in Townsville follows UTC+10 all year.

Sunlight at 19.3° S (Townsville): about 10 h 58 min of daylight in June, about 13 h 18 min in December, and a noon sun that reaches 47° in June and 86° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Townsville has a hot and humid tropical climate, which differs from the humid subtropical climate that describes Australia overall; 3 other listed cities share it.

Jobs in Townsville that call for pressure switches

In Townsville, these are the jobs that most often call for pressure switches:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Heat pump outdoor units

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

How to pick pressure switches for work in Townsville

  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Confirm the supply first: Australia uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Keeping pressure switches reliable in Townsville

  • Check that connections are leak-free and that capillary tubes are not kinked.

With little seasonal change in temperature, air conditioning in Townsville works almost every day. Spread checks of pressure switches through the year instead of waiting for a peak. Controls drift over time; verify setpoints and switch points before the demanding months.

Signs of trouble

  • Frequent unexplained compressor lockouts

Supply and delivery to Townsville

Shipments for Townsville normally clear customs at one of the main entry points of Australia and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Australia are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Pressure switches in Townsville: common questions

Can I use the same switch for R22 and R410A?

Only if its pressure range and rating cover both. R410A runs at much higher pressures, so check the model list before you order.

What voltage should pressure switches be rated for in Townsville?

The mains supply in Australia is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are pressure switches delivered to Townsville?

To order pressure switches for Townsville, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Townsville can I order for?

Enquiries are welcome from every part of Townsville. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Townsville?

Townsville keeps UTC+10 all year. At 19.3° S there are about 10 h 58 min of daylight in June and about 13 h 18 min in December.

Which cities near Townsville can the same order serve?

The listed cities closest to Townsville are Cairns (283 km north-west), Mackay (324 km south-east) and Rockhampton (597 km south-east). Combine them into one order and give each delivery address.

More Klima products for Townsville

Pressure switches in cities near Townsville