Klima Industries

Pressure switches for Nassau

As the capital of the Bahamas, Nassau is a smaller city with about 228,000 people. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.

Pressure switches are bought here mainly for offices, shops and malls as well as factories and workshops. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Nassau are welcome.

Country
Bahamas
Population
228,000
Climate
Humid subtropical
Coordinates
25.1° N, 77.3° W
Time zone
UTC-5, moving to UTC-4 while daylight saving applies
Supply
120 V, 60 Hz
Status
National capital

Klima Pressure Switches (High & Low) models

All Klima products for Nassau · Klima Pressure Switches (High & Low) overview

What Nassau demands of pressure switches

In Nassau, cooling demand peaks through a long, humid summer. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

Cities around Nassau that need pressure switches

By population Nassau is first of the 3 cities listed for the Bahamas, with roughly 76% of their combined population, about 4.9 times the size of Lucaya, the next largest. It is about the same size as San Lorenzo in Paraguay, which has 228,000.

Nearest to Nassau: Lucaya (211 km north-west) and Freeport (213 km north-west). No other listed city lies within 100 km, and two lie within 300 km. The farthest listed city in the Bahamas is Freeport, about 213 km north-west of Nassau.

CityDistancePeopleWhat wears pressure switches first
Lucaya211 km north-west47,000condensation inside enclosures
Freeport213 km north-west27,000sensor drift and setpoints creeping

In a smaller city like Nassau, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Nassau

The clock in Nassau follows UTC-5, moving to UTC-4 while daylight saving applies.

Sunlight at 25.1° N (Nassau): about 13 h 42 min of daylight in June, about 10 h 35 min in December, and a noon sun that reaches 88° in June and 42° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Nassau has a humid subtropical climate, the same as the country as a whole, and 2 other listed cities share it.

Jobs in Nassau that call for pressure switches

In Nassau, these are the jobs that most often call for pressure switches:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Heat pump outdoor units

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Nassau

  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • For humid subtropical conditions in Nassau, favour sealed, corrosion-resistant construction.

Care and maintenance in Nassau

  • Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.

In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check pressure switches in Nassau. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A unit that does not restart after a trip

Supply and delivery to Nassau

To order pressure switches for Nassau, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for the Bahamas are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Pressure switches in Nassau: common questions

Can I use the same switch for R22 and R410A?

Only if its pressure range and rating cover both. R410A runs at much higher pressures, so check the model list before you order.

What voltage should pressure switches be rated for in Nassau?

The supply in the Bahamas is 120 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a pressure switch.

How are pressure switches delivered to Nassau?

Shipments for Nassau normally clear customs at one of the main entry points of the Bahamas and finish the journey by road; send your delivery address with the enquiry.

Which parts of Nassau can I order for?

Enquiries are welcome from every part of Nassau. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Nassau?

Nassau keeps UTC-5, moving to UTC-4 while daylight saving applies. At 25.1° N there are about 13 h 42 min of daylight in June and about 10 h 35 min in December.

Which cities near Nassau can the same order serve?

The listed cities closest to Nassau are Lucaya (211 km north-west) and Freeport (213 km north-west). Combine them into one order and give each delivery address.

More Klima products for Nassau

Pressure switches in cities near Nassau