Klima Industries

Pressure switches for Pala

Pala is a smaller city in Chad. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Pressure switches are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Pala for a quotation.

Country
Chad
Population
71,000
Climate
Hot and arid
Coordinates
9.4° N, 14.9° E
Time zone
UTC+1 all year
From N'Djamena
305 km south
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Pala · Klima Pressure Switches (High & Low) overview

What Pala demands of pressure switches

In Pala, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.

Fine dust builds up on sensors and in dials; a soft brush keeps pressure switches reading accurately.

Where pressure switches go from Pala

By population Pala is 8th of the 24 cities listed for Chad, with roughly 2.5% of their combined population, about 5.2% of the size of N'Djamena, the largest. From N'Djamena, the capital, Pala is roughly 305 km to the south. It is about the same size as Antanifotsy in Madagascar, which has 71,000.

Nearest to Pala: Lere (82 km west), Kelo (99 km east) and Bongor (114 km north-east). Two other listed cities lie within 100 km, and eight within 300 km. At the other extreme, Faya-Largeau is about 1,054 km north-east of Pala, the furthest listed city in Chad.

CityDistancePeopleWhat wears pressure switches first
Lere82 km west33,000dust in enclosures and sticky switches
Kelo99 km east83,000sensor drift and setpoints creeping
Bongor114 km north-east64,000sensor drift and setpoints creeping
Deressia156 km east50,000dust in enclosures and sticky switches
Moundou156 km south-east196,000dust in enclosures and sticky switches
Bebedja198 km south-east40,000sensor drift and setpoints creeping

In a smaller city like Pala, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Pala

Pala keeps UTC+1 all year.

Pala lies at 9.4° N, 14.9° E. Daylight lasts about 12 h 40 min at the June solstice and about 11 h 35 min in December, with a noon sun 76° and 57° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Pala is hot and arid, in line with the rest of Chad; 23 other listed cities share it.

Where pressure switches are used in Pala

In Pala, these are the jobs that most often call for pressure switches:

  • Heat pump outdoor units
  • Split, VRF and packaged air conditioners
  • Water-cooled condensers and cooling-tower circuits

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Choosing pressure switches for Pala

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • Ask for the datasheet and the documents your project needs; in Chad that usually means applicable national electrical-safety and import conformity rules (generally IEC-based).

Keeping pressure switches reliable in Pala

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

Because Pala is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service pressure switches in March or April, while the load is still light. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Signs of trouble

  • Frequent unexplained compressor lockouts

Ordering pressure switches for Pala

To order pressure switches for Pala, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Chad are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Pressure switches in Pala: common questions

What does a low pressure switch do?

It stops the compressor when suction pressure falls too low, protecting it from running with too little refrigerant and preventing evaporator icing.

What voltage should pressure switches be rated for in Pala?

With a 230 V, 50 Hz supply, Chad follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.

How are pressure switches delivered to Pala?

Shipments for Pala normally clear customs at one of the main entry points of Chad and finish the journey by road; send your delivery address with the enquiry.

Which parts of Pala can I order for?

Enquiries are welcome from every part of Pala. Send the delivery address with your enquiry.

Which cities near Pala can the same order serve?

The listed cities closest to Pala are Lere (82 km west), Kelo (99 km east) and Bongor (114 km north-east). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Pala?

Pala keeps UTC+1 all year. At 9.4° N there are about 12 h 40 min of daylight in June and about 11 h 35 min in December.

More Klima products for Pala

Pressure switches in cities near Pala