Cakovice, Prague: Klima Pressure Switches (High & Low)
Cakovice is an industrial area in Prague, the Czech Republic. Typical customers are maintenance contractors, plant operators and workshops, and what they want is exact-match replacements, fast turnaround and trade quantities.
Pressure switches are bought here mainly for factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Cakovice, Prague.
- Area type
- Industrial area
- City
- Prague
- Country
- Czech Republic
- Climate
- Continental
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Cakovice, Prague ยท Klima Pressure Switches (High & Low) overview
Pressure switches and the climate in Cakovice, Prague
In Cakovice, Prague, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Wide temperature swings move rigid pipework; leave bends and clips that let the line flex, and check pressure switches connections for slow leaks each season.
For low-temperature duty, confirm that the range of pressure switches reaches below the coldest set point you need, and keep batteries fresh.
Local facts for Cakovice, Prague
Alongside Chodov, Zizkov, Vysocany and Letnany, Cakovice is one of 8 named areas in Prague, a city of about 1.2 million people, the national capital.
Plant rooms in Cakovice rely on controls that stay stable under vibration and dust; check the enclosure rating and fixing style, not only the setpoint range.
Where Cakovice fits in Prague
Of the 8 areas named for Prague, 3 are industrial areas, and Cakovice is one of them. More industrial areas in Prague, each with its own page, include Letnany and Holesovice. The rest of the areas listed for Prague are Smichov, Chodov, Zizkov, Karlin and Vysocany.
Jobs in Cakovice, Prague that call for pressure switches
Pressure switches are most often specified in Cakovice, Prague for:
- Water-cooled condensers and cooling-tower circuits
- Chillers and air-cooled condensers
- Fan speed control by head pressure
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting pressure switches in Cakovice, Prague
- Check the electrical rating against the contactor coil or control circuit it will switch.
- Ask for the datasheet and the documents your project needs; in the Czech Republic that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.
Keeping pressure switches reliable in Cakovice, Prague
- Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.
In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check pressure switches in Cakovice, Prague. Controls drift over time; verify setpoints and switch points before the demanding months.
Signs of trouble
- Frequent unexplained compressor lockouts
Ordering pressure switches for Cakovice, Prague
Send the delivery address in Cakovice, or a collection point in Prague, together with the model and quantity you need.
National rules, standards and voltage for the Czech Republic are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about pressure switches in Cakovice, Prague
How do I set the cut-out pressure?
Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.
What voltage should pressure switches be rated for in Cakovice, Prague?
With a 230 V, 50 Hz supply, the Czech Republic follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.
How are pressure switches delivered to Cakovice, Prague?
Deliveries for Cakovice are arranged to Prague; give a street address or a collection point in your enquiry.
What do buyers in Cakovice usually need?
Cakovice is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for Cakovice, Prague
- Klima Contactors in Cakovice, Prague
- Klima Filter Driers in Cakovice, Prague
- Klima Thermometers for HVAC in Cakovice, Prague
- Klima Map Gas (Brazing & Welding) in Cakovice, Prague
- Klima Condensate Pump in Cakovice, Prague
- Klima Cables (3 & 4 Core) in Cakovice, Prague
Pressure switches in other areas of Prague
- Klima Pressure Switches (High & Low) in Chodov, Prague
- Klima Pressure Switches (High & Low) in Holesovice, Prague
- Klima Pressure Switches (High & Low) in Karlin, Prague
- Klima Pressure Switches (High & Low) in Letnany, Prague
- Klima Pressure Switches (High & Low) in Smichov, Prague